odma_registers: Verification Report¶
1. Test results¶
Run on 2026-10-20 in the GHDL CI of the repository, GitHub Actions run 39467613918 on commit fee4598 (its
results.xml), with GHDL 6.0.0 (mcode), VUnit 5.0.0.dev7 and UVVM 2026.03.20:
python run.py -p 4 --xunit-xml results.xml, the tests of odma_registers_tb.
QuestaSim (Questa Pro Microchip Edition 2024.3, time resolution 1 fs) ran the tests of release 0.2.0 on commit ad726b1
with Open Logic 4.7.0-ft.10 (sources and testbenches as in fee4598), with code coverage and in the optimised run without
it, and all of them passed; the code coverage of the core is in docs/coverage.md.
The test end changed after this run (odmaTestEnd, see the verification report of odma_pkg); the tests of this bench
expect no alerts, so their results are unchanged.
| Testbench | Tests | Passed |
|---|---|---|
odma_registers_tb |
40 (24 test cases; Direct Register Mode: TC-RG-02 in two configurations, TC-RG-12 in two, TC-RG-15 in three; Scatter/Gather Mode: TC-RG-16 in five, TC-RG-17 and TC-RG-18 in three, TC-RG-19 in three, TC-RG-20 in two, TC-RG-23 in two) | 40 |
2. Summary¶
All test cases pass; every requirement of the specification is covered (see the verification plan and the compliance
matrix). VSG reports no errors and no warnings. The sources analyse with ghdl -a --std=08 without -frelaxed and
without warnings, and synthesise with ghdl --synth without warnings and without latches in the configurations of
section 3.
Findings:
| Finding | Resolution |
|---|---|
A channel accepts a command only while Run is '1'. A halt request while the command waited for Cmd_Ready would have lowered Run and left a command that is never accepted and a result that never comes |
Run stays '1' until the command is accepted; the command is never withdrawn (architecture section 4.2). TC-RG-07 requests the halt while the command waits |
A reset of olo_axi_lite_slave and of the read strobe register by the core reset would lose an access in progress at the start of the reset phase; a read would end with the timeout of the slave and SLVERR |
Both are reset by Rst only; a read during the reset phase returns the reset values (architecture section 6) |
PG021 does not describe RS = 1 written while the channel stops after a halt request |
No effect, the channel halts (interpretation R8, RG-CR-01); TC-RG-03 |
The other bits of a DMACR write with Reset = 1 would have started or reconfigured a channel for the duration of the drain |
The write only starts the soft reset (RG-CR-06); TC-RG-10 |
| The verification plan counted SEC and DED events on buffer index 15, which has no buffer | Indices without a buffer of the configuration count nothing and take no injection (RG-EX-03, RG-EX-05); TC-RG-12 and TC-RG-13 check both |
A reload of the threshold counter in the clock cycle of the DMACR write would load the old IRQThreshold |
The reload is a registered pulse one clock cycle after the write, with the new value (architecture section 5); TC-RG-21 |
PG021 leaves open what a TAILDESC write does while the channel stops after a halt request |
It only stores the pointer, as while halted (RG-SG-03); TC-RG-18 |
An error report of the engine in the clock cycle of a start would have left the channel in Started_s with Run = '0' |
The error moves the channel to Stopping_s whenever the next state is Started_s (architecture section 4.3) |
S2MM_DMACR.Keyhole can change while a transfer of Direct Register Mode runs |
The S2MM command carries the bit as stored at the write of S2MM_LENGTH (RG-SG-11); the MM2S command never carries it (interpretation I1); TC-RG-24 |
3. Generic ranges¶
| Generic | Declared range | Simulated | Synthesised |
|---|---|---|---|
IncludeSg_g |
boolean | false, true | false (core), true (odma_registers alone: AddrWidth_g 32 and 64, LengthWidth_g 8 and 26, without the S2MM channel) |
IncludeMm2s_g, IncludeS2mm_g |
boolean | true, false | true, false |
ExtRegs_g |
boolean | true, false | true, false |
AddrWidth_g |
32 to 64 | 32, 40, 64 | 32, 64 |
LengthWidth_g |
8 to 26 | 8, 26 | 8, 14, 26 |
StsCntrlStrm_g, UseRxLength_g, MicroDma_g |
boolean, configuration readback only | true, false, true | false |
Mm2s*_g, S2mm*_g (widths, burst beats, buffer beats) |
configuration readback only; the ranges are checked by the core | the values of the verification plan, section 2 | the defaults |
4. Checks of the testbench¶
Each of the following faults, inserted into a copy of the RTL, fails at least one test case; the RTL of the repository passes all of them:
| Fault | Failing test case |
|---|---|
A clear of IOC_Irq wins over a result of the same clock cycle |
TC-RG-09 |
A write of 0 to DMACR.IRQThreshold is taken |
TC-RG-02 |
| The command address follows the address register instead of the value at the length write | TC-RG-04 |
| The reset phase of a soft reset lasts 15 clock cycles | TC-RG-10 |
| All 16 ECC indices count | TC-RG-13 |
The soft reset does not wait for Stopped |
TC-RG-10 |
RS = 1 starts a channel with an error flag set |
TC-RG-08 |
An S2MM slave error does not set DMAIntErr |
TC-RG-08 |
Run falls with the halt request before the command is accepted |
TC-RG-07 |
| Register writes are taken during a soft reset | TC-RG-10 |
ECC_INJECT.Data is not taken with the strobe |
TC-RG-13 |
| The injection mode is not reset | TC-RG-13 |
| A tail pointer write passed to the engine while the channel stops | TC-RG-18 |
TAILDESC starts the engine above 32 address bits |
TC-RG-18 |
CURDESC never reads the pointer of the engine |
TC-RG-17 |
| No reload of the threshold counter by a write of the field, or at the start | TC-RG-21 |
The threshold counter sets IOC_Irq one packet late |
TC-RG-21 |
Halted without the engine stopped |
TC-RG-19 |
DMASR.Idle not gated by the run state |
TC-RG-19 |
An S2MM transfer error with the slave code without DMAIntErr; SGDecErr set by the slave code; an engine error that does not clear RS |
TC-RG-20 |
Dly_Irq not cleared by writing 1 |
TC-RG-22 |
No reload of the threshold counter at a timeout; the start of a packet does not stop the timer; the timer started by a packet that set IOC_Irq; a delay unit of 124 or 126 clock cycles |
TC-RG-22 |
| ECC index 7 counts without the S2MM channel; index 9 does not count | TC-RG-16 |
One fault is equivalent: CURDESC written while the channel runs. In every clock cycle of a running channel CurOwn
is forced to '1', so the stored value is never read; only a write while halted, which replaces the stored value,
makes it visible again. The condition on the state documents the rule of RG-SG-02.
The recovery branches of the state machines (when others) cannot be reached through the ports.