Skip to content

OpenCompact: CCSDS 123.0-B-2 Compliance Matrix

Generated by python tools/compliance.py from the requirement traceability matrix of the architecture (section 10), the requirements of the module specifications and the test cases of the module verification plans. python tools/compliance.py --check fails when a clause or a requirement has no test case, when a test case of a plan is not run by a testbench, or when this file is not up to date.

1. CCSDS 123.0-B-2 clauses

A clause is listed with every requirement whose CCSDS reference lies in the clause, and with the test cases that verify these requirements. The interpretations of the standard are listed in the sections "Interpretation of the standard" of the module specifications.

CCSDS clause Title Owner Requirements Test cases Status
3.2 Dimensions PR-1 CO-RC-01, CO-RC-07, MB-RC-02, PR-IF-01, PR-RC-01 TC-CO-52, TC-CO-57, TC-MB-05, TC-MB-07, TC-PR-01, TC-PR-05, TC-PR-08, TC-PR-11, TC-PR-12, TC-PR-13, TC-PR-18, TC-PR-19, TC-PR-20, TC-PR-22, TC-PR-34, TC-PR-41 Verified
3.3 Dynamic range PR-1 PR-IF-01 TC-PR-01, TC-PR-05, TC-PR-08, TC-PR-11, TC-PR-12, TC-PR-13, TC-PR-18, TC-PR-19, TC-PR-20, TC-PR-22, TC-PR-34 Verified
3.4 Sample coordinate indices PR-1 PR-IF-03 TC-PR-01, TC-PR-14, TC-PR-22, TC-PR-31, TC-PR-32, TC-PR-33, TC-PR-34, TC-PR-37 Verified
3.5 Supplementary information tables CO-1 CO-HD-03 TC-CO-14, TC-CO-35, TC-CO-36, TC-CO-48 Verified
4.2 Number of bands for prediction PR-2 PR-LS-01 TC-PR-01, TC-PR-02, TC-PR-07, TC-PR-11, TC-PR-13, TC-PR-24, TC-PR-34 Verified
4.3 Full and reduced prediction modes PR-2 CO-RC-07, MB-RC-02, PR-LS-02 TC-CO-57, TC-MB-05, TC-MB-07, TC-PR-01, TC-PR-02, TC-PR-12, TC-PR-24, TC-PR-34 Verified
4.4 Local sum PR-2 CO-RC-07, MB-RC-02, PR-LS-03, PR-RC-01 TC-CO-52, TC-CO-57, TC-MB-05, TC-MB-07, TC-PR-01, TC-PR-02, TC-PR-03, TC-PR-05, TC-PR-12, TC-PR-34, TC-PR-41 Verified
4.5 Local differences PR-2 PR-LS-04 TC-PR-01, TC-PR-02, TC-PR-03, TC-PR-05, TC-PR-12, TC-PR-34 Verified
4.6 Weights PR-3 PR-PD-01, PR-PD-02 TC-PR-01, TC-PR-09, TC-PR-11, TC-PR-23, TC-PR-34, TC-PR-36 Verified
4.7 Prediction calculation PR-3 PR-PD-03 TC-PR-01, TC-PR-02, TC-PR-11, TC-PR-15, TC-PR-17, TC-PR-18, TC-PR-20, TC-PR-24, TC-PR-34 Verified
4.8.1 Quantizer output PR-4 PR-QU-01 TC-PR-01, TC-PR-04, TC-PR-16, TC-PR-34 Verified
4.8.2.1, 4.8.2.2 Controlling maximum error, allowed error limit values PR-4 CO-RC-02, CO-RC-07, MB-RC-02, PR-QU-02, PR-QU-03, PR-RC-02 TC-CO-52, TC-CO-57, TC-MB-05, TC-MB-07, TC-PR-01, TC-PR-04, TC-PR-05, TC-PR-06, TC-PR-10, TC-PR-16, TC-PR-19, TC-PR-21, TC-PR-26, TC-PR-28, TC-PR-30, TC-PR-34, TC-PR-35, TC-PR-38, TC-PR-41 Verified
4.8.2.3 Error limit assignment methods PR-1 CO-RC-02, CO-RC-07, MB-RC-02, PR-QU-03, PR-RC-02 TC-CO-52, TC-CO-57, TC-MB-05, TC-MB-07, TC-PR-04, TC-PR-05, TC-PR-06, TC-PR-10, TC-PR-16, TC-PR-19, TC-PR-21, TC-PR-34, TC-PR-35, TC-PR-38, TC-PR-41 Verified
4.8.2.4 Periodic error limit updating PR-1 CH-IF-05, CO-CF-04, CO-FR-07, CO-RC-02, CO-RC-03, PR-IF-04, PR-RC-02 TC-CH-01, TC-CH-03, TC-CO-47, TC-CO-52, TC-CO-53, TC-CO-56, TC-CO-58, TC-PR-10, TC-PR-19, TC-PR-21, TC-PR-33, TC-PR-34, TC-PR-35, TC-PR-36, TC-PR-37, TC-PR-38, TC-PR-41 Verified
4.9 Sample representatives PR-5 PR-SR-01 TC-PR-04, TC-PR-06, TC-PR-26, TC-PR-29, TC-PR-34 Verified
4.10 Weight update PR-5 CO-RP-01, CO-RP-02, MB-RP-01, MB-RP-02, PR-RP-02, PR-WU-01, PR-WU-02 TC-CO-59, TC-CO-60, TC-CO-61, TC-MB-08, TC-MB-09, TC-PR-01, TC-PR-03, TC-PR-09, TC-PR-11, TC-PR-15, TC-PR-18, TC-PR-23, TC-PR-34, TC-PR-36, TC-PR-39, TC-PR-42 Verified
4.11 Mapped quantizer index PR-6 PR-MP-01 TC-PR-01, TC-PR-02, TC-PR-03, TC-PR-04, TC-PR-05, TC-PR-06, TC-PR-11, TC-PR-16, TC-PR-19, TC-PR-20, TC-PR-21, TC-PR-22, TC-PR-34 Verified
5.2 General: compressed image, output word size CO-2 CH-FN-01, CH-FN-02, CH-IF-02, CO-FR-03, CO-IF-02, CO-PK-01, CO-PK-02, CO-PK-03 TC-CH-01, TC-CH-02, TC-CO-01, TC-CO-02, TC-CO-04, TC-CO-05, TC-CO-11, TC-CO-20, TC-CO-22, TC-CO-29, TC-CO-31, TC-CO-32, TC-CO-33, TC-CO-34, TC-CO-35, TC-CO-36, TC-CO-38, TC-CO-39, TC-CO-40, TC-CO-41, TC-CO-42, TC-CO-43, TC-CO-45, TC-CO-47, TC-CO-49, TC-CO-51 Verified
5.3 Header CO-1 CH-RC-01, CH-RP-01, CO-CF-02, CO-CF-04, CO-HD-01, CO-HD-02, CO-HD-03, CO-HD-04, CO-HD-05, CO-HD-06, CO-HD-07, CO-HD-08, CO-RC-01, CO-RP-01, CO-RP-05, MB-GN-01, MB-RC-01, MB-RC-04, MB-RP-01, MB-RP-03, PK-IF-02, PK-IF-03 TC-CH-07, TC-CH-08, TC-CO-01, TC-CO-02, TC-CO-03, TC-CO-04, TC-CO-05, TC-CO-06, TC-CO-08, TC-CO-09, TC-CO-10, TC-CO-11, TC-CO-12, TC-CO-14, TC-CO-16, TC-CO-18, TC-CO-19, TC-CO-20, TC-CO-21, TC-CO-22, TC-CO-23, TC-CO-24, TC-CO-30, TC-CO-35, TC-CO-36, TC-CO-42, TC-CO-44, TC-CO-48, TC-CO-49, TC-CO-52, TC-CO-56, TC-CO-59, TC-CO-61, TC-CO-63, TC-MB-01, TC-MB-05, TC-MB-08 Verified
5.4.2 Input order PR-1 CH-IF-01, CO-CF-01, CO-FR-02, CO-IF-01, CO-RC-01, CO-RP-01, CO-RP-02, IA-FN-02, IA-IF-02, MB-RP-02, PR-FR-01, PR-FR-02, PR-IF-02, PR-IF-03, PR-IF-04, PR-RC-01, PR-RP-01, PR-TP-03 TC-CH-01, TC-CO-01, TC-CO-10, TC-CO-19, TC-CO-21, TC-CO-31, TC-CO-34, TC-CO-35, TC-CO-36, TC-CO-42, TC-CO-43, TC-CO-44, TC-CO-46, TC-CO-47, TC-CO-49, TC-CO-50, TC-CO-52, TC-CO-59, TC-CO-60, TC-CO-61, TC-IA-01, TC-IA-02, TC-MB-08, TC-MB-09, TC-PR-01, TC-PR-02, TC-PR-03, TC-PR-05, TC-PR-07, TC-PR-08, TC-PR-10, TC-PR-14, TC-PR-17, TC-PR-19, TC-PR-21, TC-PR-22, TC-PR-25, TC-PR-29, TC-PR-30, TC-PR-31, TC-PR-32, TC-PR-33, TC-PR-34, TC-PR-35, TC-PR-36, TC-PR-37, TC-PR-38, TC-PR-40, TC-PR-41, TC-PR-42 Verified
5.4.3.2 Sample-adaptive entropy coder EC-1 CO-CF-03, CO-PK-02, CO-RP-01, CO-RP-02, EC-IF-02, EC-RC-01, EC-RP-01, EC-SA-01, EC-SA-02, EC-SA-03, MB-RP-02 TC-CO-01, TC-CO-02, TC-CO-03, TC-CO-04, TC-CO-05, TC-CO-09, TC-CO-10, TC-CO-11, TC-CO-12, TC-CO-13, TC-CO-14, TC-CO-15, TC-CO-16, TC-CO-20, TC-CO-21, TC-CO-22, TC-CO-23, TC-CO-25, TC-CO-26, TC-CO-28, TC-CO-29, TC-CO-30, TC-CO-31, TC-CO-32, TC-CO-34, TC-CO-35, TC-CO-36, TC-CO-39, TC-CO-40, TC-CO-41, TC-CO-42, TC-CO-45, TC-CO-47, TC-CO-48, TC-CO-49, TC-CO-51, TC-CO-52, TC-CO-59, TC-CO-60, TC-CO-61, TC-EC-01, TC-EC-02, TC-MB-08, TC-MB-09 Verified
5.4.3.3 Hybrid entropy coder EC-2 CO-CF-03, CO-CF-05, CO-FR-03, CO-PK-02, CO-RP-01, CO-RP-02, EC-HY-01, EC-HY-02, EC-HY-03, EC-HY-04, EC-IF-02, EC-RC-01, EC-RP-01, MB-RP-02, PK-LE-01, PK-LE-02 TC-CH-02, TC-CO-01, TC-CO-02, TC-CO-04, TC-CO-05, TC-CO-10, TC-CO-11, TC-CO-13, TC-CO-16, TC-CO-20, TC-CO-21, TC-CO-22, TC-CO-26, TC-CO-30, TC-CO-32, TC-CO-34, TC-CO-35, TC-CO-36, TC-CO-39, TC-CO-40, TC-CO-41, TC-CO-42, TC-CO-45, TC-CO-47, TC-CO-49, TC-CO-51, TC-CO-52, TC-CO-59, TC-CO-60, TC-CO-61, TC-CO-64, TC-EC-01, TC-EC-02, TC-EC-05, TC-MB-08, TC-MB-09 Verified
5.4.3.4 Block-adaptive entropy coder EC-3 CO-CF-02, CO-FR-03, CO-PK-02, CO-RP-01, CO-RP-02, EC-BA-01, EC-BA-02, EC-BA-03, EC-RP-02, MB-RP-02 TC-CH-02, TC-CO-01, TC-CO-02, TC-CO-04, TC-CO-05, TC-CO-06, TC-CO-07, TC-CO-08, TC-CO-11, TC-CO-17, TC-CO-18, TC-CO-19, TC-CO-20, TC-CO-22, TC-CO-24, TC-CO-27, TC-CO-33, TC-CO-35, TC-CO-36, TC-CO-39, TC-CO-40, TC-CO-41, TC-CO-42, TC-CO-44, TC-CO-45, TC-CO-47, TC-CO-49, TC-CO-51, TC-CO-59, TC-CO-60, TC-CO-61, TC-EC-03, TC-MB-08, TC-MB-09 Verified

Clauses: 23; verified: 23; not traced: 0.

2. Requirements

Requirements of the module specifications and the test cases that verify them (requirements without a CCSDS reference included).

Module Requirements Verified by a test case Without a test case
ocp_channel 14 14 -
ocp_core 44 44 -
ocp_entropy_coder 18 18 -
ocp_input_adapter 13 13 -
ocp_mib 17 17 -
ocp_pkg 5 5 -
ocp_predictor 32 32 -

Requirements: 143; without a test case: 0; test cases of the plans not run by a testbench: 0.