Skip to content

ocp_input_adapter

Input adapter of an OpenCompact channel: takes service data units (SDUs) of big-endian sample containers of ceil(D/8) bytes from a byte stream of 8 to 128 bits and outputs one sample per beat to ocp_core with the image framing. The user signal of an SDU marks the last SDU of an image and flags faulty SDUs; a faulty SDU, or one that does not hold a whole number of samples, ends its image with an error, and the rest of that image is discarded.

Document Content
Specification Requirements, partner behaviour of the SDU source, error conditions, generics
Architecture Width converter, sample extraction, SDU control, the In_Error input of the core
Verification plan Test cases with a reference model of the adapter
Verification report Results

Tests: python run.py "*ocp_input_adapter*"