Skip to content

spp_mib: Architecture

1. Block diagram

Block diagram of spp_mib: bus interface (olo_axi_lite_slave), register file (MG-1) and EDAC monitor
(olo_ft_ecc_monitor, MG-2)

2. Register access

Writes are decoded in the cycle of Rb_Wr; a clear of a counter is applied before the events of the same cycle, so no event is lost. Reads latch the address with Rb_Rd and answer one cycle later, except a read of a table entry register while an access of its table is pending or the table initialises: the read stays pending until the access is complete. The read timeout of the AXI4-Lite slave (4096 cycles) covers the initialisation of a table (2048 cycles).

3. Table access

One state machine per table, client B of the table:

State machine of a table access: TIdle_s, TReq_s, TWait_s, TDone_s

A write of the APID register sets a read request, a write of the entry register a write request with its data; the transaction always reads the entry first (the table protocol), then writes the new data or releases the entry. The entry register shows the data written or the entry read with its double error flag. A write to the APID or entry register while a request is pending or running is ignored and sets the overrun flag.

4. Counters and events

The error counters are indexed by the error code. Every cycle, the events of all sources are compared with each code and the number of matching events is added with saturation. The source of the lowest index with an event is stored as the last error and output on Err_* one cycle later. The packet counters add the number of Rx_Delivered bits set. The event flags are set by the events and by Evt_Sec and Evt_Ded of the EDAC monitor; the interrupt is registered.

5. EDAC monitor and injection

olo_ft_ecc_monitor counts the SEC and DED pulses of 8 channels: 0 send data buffers, 1 send descriptor buffers, 2 send APID table, 3 its scrubber, 4 receive data buffer, 5 receive descriptor buffer, 6 receive APID table, 7 its scrubber. A write of ECC_INJECT with SINGLE or DOUBLE produces a one-cycle injection command with the channel and the end (RX bit); the sending and receiving ends apply it to the next write of the selected buffer or table.

6. Ports

Port Width Direction Description
Clk, Rst 1 in Clock, synchronous high-active reset
S_AxiLite_* 11-bit address, 32-bit data AXI4-Lite slave
Irq 1 out Interrupt
Cfg_* out Managed parameters and destinations (see spp_encapsulation, spp_send, spp_receive)
TxTbl_*, RxTbl_* Client B of the send and the receive APID table; *_Busy inputs during their initialisation
Err NumErr_g events in Error events of all sources
Tx_Sent, Rx_Delivered, Rx_Loss 1, NumRx_g, 1 in Packet events
Err_Valid, Err_Code, Err_Port, Err_Apid 1, 5, 4, 11 out Error event output
Ecc_Sec, Ecc_Ded 8 in ECC events of the 8 channels
Inj_TxValid, Inj_RxValid, Inj_Channel, Inj_Double 1, 1, 6, 1 out Injection commands

The register map lists every register and field.