Skip to content

spp_send: Architecture

1. Block diagram

Block diagram of spp_send: send buffers (SE-1) per user port, multiplexer (SE-2), packet assembly (SE-3)
and send APID table (TB-1)

2. Send buffer (SE-1, spp_send_buffer)

The buffer checks an SDU while it arrives and writes it into an olo_ft_fifo_packet (data only, DataWidth_g bits per word, feature set DROP_SKIP_ONLY). At the last beat the checks of SE-BF-02 to SE-BF-04 decide in a fixed order:

Order Octet String port Packet Service port
1 Oversize (0x01) Oversize (0x01)
2 Without any byte (0x02) Shorter than 7 bytes (0x02)
3 Idle APID with SHI (0x05) Version not '000' (0x03)
4 Packet Name of a telemetry packet (0x06) Length not PDL + 7 (0x04)
5 Idle APID with SHF (0x05)

The byte count adds the set bits of Keep of every beat, so a last beat without byte enables (D15) adds nothing: the SDU consists of the bytes of the earlier beats, and the beat itself is stored like any other.

A failed SDU is dropped with In_Drop together with its last beat and reported. The oversize check runs on every beat: once the byte count exceeds the limit, In_Drop is asserted and the rest of the SDU is consumed. The byte count saturates at 2^17 - 1. A Space Packet's first six bytes are captured from fixed beat and lane positions (byte k in beat k / B, lane k mod B), including the current beat, so that the checks at the last beat see the complete header.

An accepted SDU writes a descriptor into an olo_ft_fifo_sync of MaxPackets_g entries:

Bits Content
16:0 Byte length of the SDU
44:17 TUser of the request (Octet String) or the APID of the header in bits 27:17 (Space Packet)

The input is ready when both FIFOs are ready. The data FIFO accepts at most MaxPackets_g packets, so the descriptor FIFO never overflows.

3. Multiplexer (SE-2, spp_send_mux)

olo_base_arb_prio (latency 0) and olo_base_arb_rr arbitrate among the ports with a descriptor. Port 0 is mapped to the left-most request bit, the highest priority of both arbiters. Cfg_RoundRobin selects the grant; the round-robin arbiter advances only when its grant is taken.

4. Packet assembly (SE-3, spp_send_assembly)

The assembly has two state machines that work concurrently, so that the preparation of the next packet overlaps the transfer of the current one.

State machines of the packet assembly: preparation (PIdle_s to PJob_s) and transfer (SIdle_s,
SStream_s)

PWrite_s decides with the entry of the APID: a double error or a disabled path makes a job that drops the SDU and reports it; an Octet String gets its header, and the entry is written back with the incremented count unless a Packet Name is used (then it is released); a Space Packet releases the entry. The job holds the port, the drop flag, the header and its length (6 or 0), the byte length and the destination.

SStream_s reads the data FIFO of the job's port. A dropped SDU is skipped with Out_Next on its first word, which ends it at once. Otherwise every word goes through spp_header_insert with the job's header; the byte enables and Last of the last word follow from the remaining byte count. When a stored word without bytes follows (a last beat without byte enables at the port, D15), it is skipped like a dropped SDU, so no beat without bytes leaves the output. A double error in any word sets the EEP flag of TUser with the last beat.

The table transaction takes four cycles and the job register lets it run during the transfer of the previous packet; in simulation, packets of 256 bytes leave the output without a gap (SE-PF-01).

5. Ports

Port Width Direction Description
Clk, Rst 1 in Clock, synchronous high-active reset
S_Tx_Valid, S_Tx_Ready, S_Tx_Last NumTx_g in, out, in Handshake and end of SDU per port
S_Tx_Data NumTx_g x DataWidth_g in SDU bytes, port p in the bits of index p
S_Tx_Keep NumTx_g x DataWidth_g/8 in Byte enables
S_Tx_User NumTx_g x 28 in Parameters of OCTET_STRING.request (unused for Packet Service ports)
M_Pkt_* DataWidth_g out, in Space Packets (Valid, Ready, Data, Keep, Last), User: EEP (bit 0), destination (4:1)
Cfg_MaxLength, Cfg_RoundRobin, Cfg_TableInit 17, 1, 19 in Managed parameters, initial table entry
Tbl_* Client B of the send APID table; Tbl_Busy during its initialisation
Err NumTx_g + 1 events out Index p: send buffer of port p; index NumTx_g: assembly
Sent 1 out A Space Packet left the output
Ecc_Sec, Ecc_Ded 4 out ECC events: 0 data buffers, 1 descriptor buffers, 2 table reads, 3 scrubber
ErrInj_Channel, ErrInj_Double, ErrInj_Valid 6, 1, 1 in Injection into the next write: channel 2p data buffer of port p, 2p + 1 its descriptor buffer, 2 NumTx_g table
Scrub_Enable 1 in Scrubber of the table enabled

6. Send APID table entry

Bits Field
13:0 Packet Sequence Count of the next Octet String
17:14 Destination index
18 Managed data path enabled