spp_packetizer: Architecture¶
1. Block diagram¶
The packetizer has an input side and an output side, coupled by two FIFOs with SECDED protection. The input side
cuts the data units into segments and writes every segment into the segment buffer (olo_ft_fifo_packet) and its
descriptor into the descriptor FIFO (olo_ft_fifo_sync). The output side takes the next complete segment, builds its
headers, and passes the segment through the header insertion (spp_header_insert) and the CRC trailer to the output.
2. Input side: segmenter¶
2.1 Hold register¶
The segmenter holds the latest accepted beat of a data unit in a hold register until the next beat shows how the data
unit continues. A beat is written into the segment buffer when the next beat of the input is accepted, or in the next
clock cycle when the held beat carries Last itself. This answers two questions that the last data beat cannot
answer alone:
- Is a full segment the last one of its data unit? A segment of
ChunkBytes_gbytes whose last beat has noLastis the last segment only if the next beat is a last beat without byte enables (PT-SG-04). - Where does a data unit end that ends with a last beat without byte enables (PT-IF-04, D15)? The held beat becomes the last beat of the segment; the beat without bytes is not written.
When the held beat is written, In_Last of the segment buffer marks the end of a segment: the beat completes
ChunkBytes_g bytes, or it is the last data beat of its data unit. Writing the held beat and accepting the next
beat happen in the same clock cycle, so the input accepts one beat per clock cycle while the buffer has room.
A data unit without any byte (a last beat without byte enables while the hold register is empty) is discarded.
Aborted is '1' for one clock cycle when a last beat with S_Error = '1' is accepted, with or without bytes.
2.2 Segment length and CRC¶
A byte counter counts the bytes of the current segment: DataWidth_g/8 for every beat except the last beat of a
data unit, whose bytes follow from S_Keep. With Crc_g set, olo_base_crc processes every beat written into the
segment buffer (In_Last at the end of a segment, In_Be the byte enables of the beat) with the parameters of
PT-CR-01: Polynomial_g = x"1021", InitialValue_g = x"FFFF", BitOrder_g = "MSB_FIRST", ByteOrder_g =
"LSB_FIRST" (byte lane 0 first). The CRC of a segment is available one clock cycle after its last beat; the
descriptor is therefore written one clock cycle after the last beat of its segment, with or without CRC.
2.3 Descriptor¶
| Bits | Field | Content |
|---|---|---|
| 15:0 | Length | Number of bytes of the segment minus one (0 to 65535) |
| 16 | First | The segment is the first one of its data unit |
| 17 | Last | The segment is the last one of its data unit |
| 33:18 | CRC | CRC of the segment, bit 15 first transmitted (only with Crc_g) |
The descriptor FIFO has MaxChunks_g entries, as many as the segment buffer has packets. A descriptor is read when
the header of its packet is built, before the segment leaves the buffer, so the descriptor FIFO always has room for
the descriptor of a segment the buffer accepted.
2.4 Segment buffer¶
olo_ft_fifo_packet with Width_g = DataWidth_g, Depth_g = BufferBytes_g / (DataWidth_g/8) and
MaxPackets_g = MaxChunks_g. It works store and forward: a segment is visible at the output only when its last
beat is written. Its packet boundaries are held in flip-flops (SmallRamStyle_g = "registers"), outside the
SECDED code, so a double error in a data word never changes the framing. The buffer frees the space of a segment when
the segment has been read completely; with BufferBytes_g = 2 × ChunkBytes_g the next segment is written while the
packet before it leaves.
3. Output side¶
3.1 Packet control¶
| State | Action | Next state |
|---|---|---|
Idle_s |
Waits for a complete segment in the buffer and its descriptor. When both are present: Hdr_Sample = '1', the header register takes the Packet Primary Header and SecHdr_Data, the CRC register takes the CRC, the descriptor is read and the count is incremented |
Data_s |
Data_s |
Passes the beats of the segment from the buffer to the header insertion; Keep is all ones except for the last beat, whose valid bytes follow from the length |
Idle_s after the last beat |
others |
Recovery | Idle_s |
The header of the next packet is taken in Idle_s, at the earliest one clock cycle after the last beat of the
packet before it has entered the header insertion. The insertion samples the header register with the first beat of a
packet, so the register is stable from the moment it is taken until the insertion has used it.
Packet Primary Header (primaryHeader of spp_pkg):
| Field | Value |
|---|---|
| Packet Version Number | '000' |
| Packet Type | Cfg_Type |
| Secondary Header Flag | '1' when SecHdrBytes_g > 0 |
| APID | Cfg_Apid |
| Sequence Flags | First and Last: '11'; First: '01'; Last: '10'; neither: '00' |
| Packet Sequence Count | Count register (14 bits), incremented modulo 16384 with every header |
| Packet Data Length | SecHdrBytes_g + Length + 1 (+ 2 with Crc_g) - 1 |
3.2 Timing of Hdr_Sample¶
Clk _/‾\_/‾\_/‾\_/‾\_/‾\_/‾\_
Hdr_Sample ___/‾‾‾\_____________
SecHdr_Data ==X=== A ===X======== sampled at the rising edge that ends the Hdr_Sample cycle
M_Valid ___________/‾‾‾‾‾‾‾‾‾ first beat of the packet: at the earliest two cycles later
Cfg_Apid, Cfg_Type and SecHdr_Data are sampled at the rising edge of Clk that ends the cycle in which
Hdr_Sample is '1'. The first output beat of the packet follows at the earliest in the second cycle after that
(header insertion with registered output). A user who presents a time code on SecHdr_Data gets the time of that
edge.
3.3 Header insertion¶
spp_header_insert with MaxHeaderBytes_g = 6 + SecHdrBytes_g and the constant header length 6 +
SecHdrBytes_g: the header register supplies the Packet Primary Header in bytes 0 to 5 and SecHdr_Data in the
bytes after it. The insertion shifts the segment behind the header and keeps one beat per clock cycle. User of the
insertion carries the CRC of the segment to the last beat of the packet.
3.4 CRC trailer¶
With Crc_g set, the trailer appends the two CRC bytes behind the last valid byte of every packet, bits 15:8 first.
When the last beat has room for both bytes, they fill its next lanes; otherwise the trailer adds one beat (or two at a
width of 8 bits). The trailer holds one output beat in a register and keeps one beat per clock cycle, except for the
added beat. Without Crc_g the trailer is not instantiated.
4. Ports¶
| Port | Width | Direction | Description |
|---|---|---|---|
Clk, Rst |
1 | in | Clock, synchronous high-active reset |
S_Valid, S_Ready |
1 | in, out | Handshake of the input data units |
S_Data, S_Keep |
DataWidth_g, DataWidth_g/8 |
in | Bytes and byte enables, byte lane 0 first |
S_Last |
1 | in | Last beat of a data unit |
S_Error |
1 | in | With S_Last: the data unit was aborted |
M_Valid, M_Ready |
1 | out, in | Handshake of the output Space Packets |
M_Data, M_Keep |
DataWidth_g, DataWidth_g/8 |
out | Bytes and byte enables |
M_Last |
1 | out | Last beat of a Space Packet |
Cfg_Apid |
11 | in | APID of the packets |
Cfg_Type |
1 | in | Packet Type |
SecHdr_Data |
8 × max(SecHdrBytes_g, 1) |
in | Packet Secondary Header, bits 7:0 first byte (unused when SecHdrBytes_g = 0) |
Hdr_Sample |
1 | out | One cycle per packet: Cfg_* and SecHdr_Data are sampled at the end of this cycle |
Aborted |
1 | out | One cycle per accepted last beat with S_Error |
Ecc_Sec, Ecc_Ded |
2 | out | One cycle per corrected or detected error; bit 0 segment buffer, bit 1 descriptor FIFO |
ErrInj_Data, ErrInj_Desc |
1 | in | Inject into the next word written into the buffer or the descriptor FIFO |
ErrInj_Double |
1 | in | '0': flip data bit 0 (single error), '1': data bits 0 and 1 (double error) |
The injection flips data bits, not parity bits, so a single error shows that the output uses the corrected data and a double error shows its consequence in the packet (codeword positions 3 and 5 of the Open Logic SECDED code).
5. Error behaviour¶
| Event | Behaviour |
|---|---|
| Single error in a segment word or a descriptor | Corrected on reading, Ecc_Sec pulse when the word is read |
| Double error in a segment word | Ecc_Ded(0) pulse; the beat leaves as read, the packet is complete and correctly framed; with Crc_g the CRC at the receiver does not match |
| Double error in a descriptor | Ecc_Ded(1) pulse; the packet leaves with the fields as read and with the beats of its segment in the buffer. A corrupted length that gives another number of beats makes the Packet Data Length differ from the bytes of the packet, which the length check of the send port of spp_core rejects (reason 0x04). A corrupted length with the same number of beats (an error in its lowest bits, for example 4095 to 4092 at 32 bits) only changes the valid bytes of the last beat: the packet matches its own Packet Data Length, with bytes of the segment missing or with bytes of the buffer that are not part of it, and the core sends it; with Crc_g the receiver detects it by the CRC, without Crc_g only Ecc_Ded(1) reports it. Corrupted Sequence Flags reach the receiver as an inconsistent flag sequence, a corrupted CRC as a CRC that does not match |
| Aborted data unit | Segmented and sent as usual (PT-SG-03), Aborted pulse |
| Reset | Both FIFOs and the hold register are emptied, the state machine returns to Idle_s, the count to 0; S_Ready is '0' while Rst is '1', so no beat offered during the reset is accepted and lost |
6. Resources¶
The segment buffer is the main resource: BufferBytes_g bytes plus the SECDED bits of every word (for example
8 bits per 32-bit word, 9 bits per 128-bit word). The descriptor FIFO holds MaxChunks_g words of 18 bits, or 34
with the CRC, plus their SECDED bits.