Skip to content

owr_encoding: Verification Report

1. Test results

Run on 2026-10-14 with GHDL 6.0.0 (mcode), VUnit 5.0.0.dev7, UVVM 2026.03.20: python run.py "*owr_encoding*".

Testbench Tests Passed
owr_encoding_tb 28 (4 transmit tests; 8 receive tests in sync_2, sync_3 and sync_4) 28

QuestaSim (Questa Pro Microchip Edition 2024.3), complete regression without code coverage (python run.py --questa -p 1) on 2026-11-18 with Open Logic 4.8.0-ft.2 (release 0.1.1): all 28 tests of owr_encoding_tb pass. On 2026-10-16 with Open Logic 4.7.0-ft.6 and the same RTL they passed without code coverage and with it.

2. Summary

All 28 test cases pass, the receive tests with 2, 3 and 4 synchroniser stages; every requirement of the specification is covered (see the verification plan). VSG reports no errors and no warnings.

Findings:

Finding Resolution
The transmitter took the presented character as its first character after Transmit Enable; ECSS 5.4.5 requires a Null EN-1 sends a Null as the first character and takes the presented character only if it is a Null (EN-TX-06)
The reset input set data and strobe to '0' in the same cycle, a simultaneous transition when both were '1' (ECSS 5.4.4c) Strobe is reset in the first and data in the second cycle of the reset (EN-TX-07)
Transmit Enable asserted again before the end of the controlled reset left data or strobe at '1' and the transmitter inactive until Transmit Enable was de-asserted again (found by the condition coverage) The controlled reset continues while the transmitter is inactive; the restart follows at a bit boundary (EN-TX-07). In the core the link state machine keeps Transmit Enable low for at least 19.2 us, so the core was not affected
A first Null followed by a data character is not detected by a receiver (its last parity bit is '1') Correct behaviour of ECSS 5.4.6 (Figure 5-18); the tests send a control character after the first Null, as the Started state does

Observations:

  • The receiver decodes a far-end bit period of 12 ns with a 100 MHz clock (1.2 clock periods); the model has no jitter, so the margin for skew and jitter on a real line is the difference to one clock period.
  • After a simultaneous transition the receiver reported a parity or ESC error within 4 us in all 20 cases.
  • Data and strobe pass the triplicated synchroniser olo_intf_sync (three chains and a majority voter). Its latency equals that of one chain, so the disconnect time and the receive timing are the same as with a single chain; all 12 test cases pass unchanged.