Skip to content

owr_network: Verification Report

1. Test results

Run on 2026-10-14 with GHDL 6.0.0 (mcode), VUnit 5.0.0.dev7, UVVM 2026.03.20: python run.py "*owr_network*".

Testbench Tests Passed
owr_network_tb 15 (12 in the default configuration; TC-NI-11 in no_services, time_codes_only, interrupts_only) 15

QuestaSim (Questa Pro Microchip Edition 2024.3), complete regression without code coverage (python run.py --questa -p 1) on 2026-11-18 with Open Logic 4.8.0-ft.2 (release 0.1.1): all 15 tests of owr_network_tb pass. On 2026-10-16 with Open Logic 4.7.0-ft.6 and the same RTL they passed without code coverage and with it.

2. Summary

All 15 test cases pass; every requirement of the specification is covered (see the verification plan). VSG reports no errors and no warnings. The minimum interval of 5 ticks of 100 ns was measured as 500 ns to 600 ns plus the request latency.

Findings: none in the design. During reset the outputs of the interrupt service are undefined in simulation (the registers are reset at the first clock edge); the slot model of the testbench ignores them while the reset is active.