Skip to content

ocr_ghash: Architecture

1. Structure

Block diagram of ocr_ghash: block assembly, block queue, digit-serial multiplier, output register and the register of
the next hash subkey

2. Block assembly

The assembly writes the bytes of each beat into the block register X at the position of beat K of the block (beatToBlock), with the lanes without byte enable zero. A block is complete after R = 128 / DataWidth_g beats or at the end of a section (zero padding); an empty section has no block. After the last beat of a message the assembly pushes the length block in the next cycle (LenPending), during which it does not take a beat. The byte counts of the AAD and of the ciphertext saturate at 2LenBits_g - 1 and set the length error.

A queue entry holds X, the flags "first block of the message" and "length block", and the length and ECC errors of the message; the byte counts of the result are taken from the length block. The queue is an olo_base_pl_stage of one stage for a 128-bit digit and of three stages otherwise: a multiplier that needs several cycles per block falls behind on the short blocks of short sections and catches up in its idle cycles of long sections; three stages give it room for that (GH-PF-01).

3. Multiplier

For every block the multiplier runs s = 128 / Digit_g steps. Step k takes the digit k (from the rightmost bits of the block) of A = Y ⊕ X (A = X for the first block of a message, GCM 6.4 step 2) and computes Z := Z · uD + digit · H (gfMulDigit, Z = 0 in step 0). After the last step Y := Z; Y stays the result of the previous block during the steps, so the next block starts in the following cycle without a gap. The hash subkey of a message is loaded into H with the first block; the register of the next hash subkey is refilled in the same cycle. The result of the length block is S; the multiplier waits when the output register still holds the S of the previous message.

4. Timing

Digit Cycles per block Use (architecture D5)
128 1 Default for 64 and 128 bits
64 2 Default for 16 and 32 bits
32 4 Smaller multiplier, full rate for long messages at 16 and 32 bits
16 8 Smallest multiplier at 16 bits

The critical path is the digit multiplication with the reduction (an XOR tree over up to 128 · D / 128 products per result bit) plus the XOR of Y and X on the digit.