Skip to content

ocr_packer: Specification

1. Overview

ocr_packer is the output packer (block OU-4 of the architecture) of the dense output of ocr_core (DenseOutput_g). The output assembly starts every section of a message with a new beat, so a section that does not end on a beat boundary leaves a partial beat in the middle of the message. The packer closes these gaps: the message leaves as one gapless byte stream in which only the last beat is partial. The bytes, their order and the error flag of the message stay unchanged.

2. Requirements

2.1 Interfaces

ID Requirement Clauses
PA-IF-01 The input and the output shall be AXI4-Stream ports of DataWidth_g bits (16, 32, 64 or 128) with Keep, Last and User, in Clk with the synchronous high-active reset Rst. Input format: the sectioned output messages of the output assembly (section code in User(1:0), error flag on the last beat in User(2), valid bytes contiguous from lane 0, a beat without valid byte only as the only beat of a message). none (architecture section 6)
PA-IF-02 DataWidth_g shall be 16, 32, 64 or 128; any other value shall stop the elaboration. none (architecture D4, D6)

2.2 Function

ID Requirement Clauses
PA-FN-01 The output shall carry the bytes of every message in their input order without gaps: every beat except the last beat of a message carries DataWidth_g / 8 bytes, the last beat the remaining bytes, contiguous from lane 0. A message without any byte shall leave as one beat without valid byte. none (D14)
PA-FN-02 User(1:0) of an output beat shall be the section of its first byte; for a beat without valid byte, the section of its input beat. none (D14)
PA-FN-03 The error flag of the last input beat of a message shall be on the last output beat of the message; User(2) of every other output beat shall be '0'. none (D14)
PA-FN-04 No byte shall be lost or duplicated for any pattern of cycles without valid at the input and without ready at the output. none (D3)
PA-FN-05 The reset shall clear the bytes of the message in progress and restart the packer from any state. none (D13)

2.3 Performance

ID Requirement Clauses
PA-PF-01 While the output is ready, the input shall accept one beat per clock cycle, except one cycle after the last beat of a message whose bytes do not fit into the output beats before it (the packer sends the rest in an extra output beat). none (D3)

3. Interpretation of the standard

The packer changes the framing of the output stream only; it does not touch the bytes of the AAD, of the ciphertext or plaintext and of the tag, and so has no clause of FIPS 197, NIST SP 800-38D or CCSDS 352.0-B-2.

4. Configuration parameters

Generic Default Range Description
DataWidth_g 32 16, 32, 64, 128 Width of the message streams