Skip to content

ocan_axi: Architecture and Design Description

1. Block diagram

Block diagram of ocan_axi: the reset generator olo_base_reset_gen for the register interface, ocan_core with the
transceiver ports and the NODE-ID pins, and ocan_mib with the AXI4-Lite slave and the interrupt, connected port by
port

ocan_axi instantiates ocan_core, ocan_mib and olo_base_reset_gen. Every port of ocan_core other than Clk, Rst, Can_* and Pin_* connects to the port of the same name of ocan_mib (AX-CN-01): the outputs of the core to the inputs of the register interface and the control, bit timing, PDO, application port, time request and error injection outputs of the register interface to the inputs of the core. The generics of the core go to both instances, so the identification registers describe the instantiated node (AX-CN-02).

2. Reset

Rst is asynchronous and high-active. ocan_core synchronises its release with its own olo_base_reset_gen (CO-1); ocan_axi synchronises it a second time for ocan_mib and olo_axi_lite_slave, with the same generics (RstPulseCycles_g = 3, SyncStages_g of the core, SyncTmr_g = true). Both outputs assert while Rst is '1' and release after the three stages of the reset chain and the SyncStages_g stages of the synchroniser; because each synchroniser resolves the asynchronous edge of Rst on its own, the two releases can differ by one clock cycle. The order does not matter at the ports:

Released first In the cycle of the difference Why nothing is lost
ocan_core ocan_mib drives its reset values: Ctrl_Enable = AutoEnable_g, the bit timing of the generics, no request, the application port at its default values, no injection These are the values that ocan_mib drives after its release, so the core sees the same inputs. No event of the core occurs in that cycle: ocan_nmt waits two clock cycles in Init_s before its first event, and the controllers integrate for 11 recessive bits before they take part in the bus.
ocan_mib The register interface answers accesses while the core is still in reset An AXI4-Lite write takes effect at the earliest in the third clock cycle after the write address (address, data, write), so no register write and no command pulse reaches the core before its release; levels such as CONTROL.ENABLE are held and seen by the core when it starts. A read samples the status in the clock cycle after its read address, when the core runs.

TC-AX-02 releases the reset with a read and a write queued for the first cycles and with a frame of a model node on the bus at four positions of the frame; the accesses complete with their effect, the frame ends without an error and the node joins the bus after it.

3. Ports of ocan_axi

Signal Direction Width Description
Clk, Rst In 1 Clock; asynchronous high-active reset, the hardware reset of the node
S_AxiLite_* AXI4-Lite slave of ocan_mib: ArAddr, AwAddr 9 bits, WData, RData 32 bits, WStrb 4 bits (not used), BResp, RResp 2 bits, handshakes
Irq Out 1 Interrupt of ocan_mib
Pin_NodeId, Pin_NodeIdCode In 7, 7 NODE-ID pins and their complement (CO-IF-03)
Can_Tx, Can_TxEn, Can_Rx Out, Out, In 2, 2, 2 Transceivers of bus A (index 0) and bus B (index 1); Can_Rx defaults to "11"

4. Configuration parameters

The generics of ocan_core (user guide, section 2) and AutoEnable_g, Prescaler_g, Tseg1_g, Tseg2_g, Sjw_g and ErrInjRegs_g of ocan_mib, with their names, defaults and ranges. The generic checks of both instances apply.

5. Protection

ocan_axi adds the reset synchroniser of the register interface: three synchroniser chains and a majority voter (SyncTmr_g = true), as every crossing of the family. All other protection is that of ocan_core and ocan_mib (user guide, section "Protection scope").