Skip to content

ocan_link: Verification Report

1. Test results

Run with GHDL 6.0.0 (mcode), VUnit 5.0.0.dev7 and UVVM 2026.02.14: python run.py "*ocan_link_tb*".

Testbench Test cases Runs (test case and configuration) Passed
ocan_link_tb 19 32 32

The configurations are those of section 2 of the verification plan. The far end of every test is the CAN network model of tb/, whose encoding and receiver are checked against six frames of real buses (tb/ocan_tb_can_model_tb.vhd, 8 tests).

QuestaSim (Questa Pro Microchip Edition 2024.3): the same tests pass in the regression without code coverage (python run.py --questa -p 1) and with it (python run.py --questa --coverage -p 1); the coverage is in docs/coverage.md.

2. Measured values

Item Value
Received frame to Rx_Valid, measured from the receiver of the model 150 ns on bus A and bus B, in both bus access architectures, for every frame of TC-LK-01 (the model samples at 75 % of the bit, the link at 80 %)
Bus switch without a pending frame 2 clock cycles of Stat_Switching (TC-LK-06)
First bit after a switch 11.0 bit times after the controller is enabled again (integration, TC-LK-06)
Dominant timeout at DominantLimit_g = 13 and 32 13.025 µs and 32.025 µs at 1 Mbit/s after the transmit bit became dominant (TC-LK-14)
Longest dominant sequence of the controller in blind mode, from a transmit count of 0 17 bit times (start of frame and 16 restarted active error flags), no dominant timeout (TC-LK-16)
Bus-off recovery after 128 x 11 recessive bits, then the pending frame is sent (TC-LK-11, TC-LK-12)
Back-to-back frames every frame passed; consecutive events exactly the frame length plus 2 bit times apart (TC-LK-17)
Stop state copies made unequal on a stopped controller released in the cycle after the injection; stopped again in the next cycle, with Err_DomTimeout, while the transmit bit is still dominant (TC-LK-19)
Re-enable while the transmit bit is still dominant stopped again in the next cycle, with Err_DomTimeout (TC-LK-19)
Tx_Stopped '1' while the controller of the active bus is stopped, also after a switch to the bus of a stopped controller; '0' while only the controller of the inactive bus is stopped (TC-LK-14, TC-LK-15)

3. Generic ranges

Generic Declared range Simulated Synthesised (lint/synth_check.py)
BusAccess_g "Selective", "Parallel" both both; another value is rejected
SyncStages_g 2 to 4 2, 3, 4 2, 3, 4
AutoRecover_g true, false both both
DominantLimit_g 13 to 1023 13, 32, 1023 13, 32, 1023

4. Negative tests and mutations

Every checker of the plan has a negative test (verification plan, section 5). In addition, 18 deliberate faults of the RTL were each simulated with the tests that must detect them, and every one made a test fail:

Fault Detected by
The inactive bus is driven TC-LK-02 and the bus checker of every test
The controller of the inactive bus is not in listen-only mode TC-LK-02
No abort of the pending frame at a disable TC-LK-09
No abort of the pending frame before a switch TC-LK-07
The dominant monitor never stops a controller TC-LK-14
The re-enable request has no effect TC-LK-14
Frames of bus B are passed as frames of bus A (selective bus access) TC-LK-01
Frames are taken during a bus switch TC-LK-07, TC-LK-08, TC-LK-09
A switch keeps the old bus TC-LK-06
The active bus after the enable ignores the requested bus TC-LK-06, TC-LK-09
The dominant monitor counts one quantum too many per bit TC-LK-14
A disable does not clear a stopped controller TC-LK-14
The dominant timeout only at the step to the limit (=) TC-LK-19
Unequal stop state copies stop the controller TC-LK-19
The complement of the stop state not used TC-LK-19
No repair of unequal stop state copies TC-LK-19
ErrInj_StopFlip without effect TC-LK-19
Tx_Stopped of controller 0 instead of the controller of the active bus TC-LK-15

All 18 faults ran on the RTL with the protected stop state. The robustness change moved the text of five faults of the first check (no abort while disabled, the monitor never stops, no re-enable, Tx_Ready while switching, a stopped controller kept at a disable); each was simulated again as the same fault at its new place. The compare with = of the dominant monitor is detected at the ports: TC-LK-19 releases a stopped controller whose transmit bit is still dominant, which only the compare with >= stops again.

5. Summary

All 19 test cases pass in all 32 runs; every requirement of the specification is covered by the verification plan. VSG reports no errors and no warnings, and the GHDL synthesis of every configuration has no inferred latch.