ocan_dispatch: Architecture and Design Description¶
1. Block diagram¶
ocan_dispatch is one entity with one two-process record. It instantiates olo_base_arb_rr for the transmit
arbitration and runs in Clk. It has no frame memory (D11 of the architecture).
2. COB-ID table and protection (DS-4)¶
ocan_od supplies the configured COB-IDs as two copies of a table of 12 entries, Cfg_CobId and Cfg_CobIdCopy,
with 12 bits per entry. Bit 11 is the valid flag ('1': the object is valid) and bits 10 to 0 are the identifier.
| Entry | Object | Direction |
|---|---|---|
| 0 | SYNC | Receive |
| 1 | Spacecraft Time PDO | Receive |
| 2 to 5 | Receive PDO 1 to 4 | Receive |
| 6 to 9 | Transmit PDO 1 to 4 | Transmit |
| 10 | Local Time PDO | Transmit |
| 11 | Master heartbeat (700h + NODE-ID of the Redundancy Master) | Receive |
A registered flag Usable(e) is set for entry e when four conditions hold:
- both copies are equal;
- the valid flag is set;
- the identifier is outside the free ranges 781h to 7DEh and 7F0h to 7FFh (DS-TX-05);
- the entry exists for the generics (
NumRpdo_g,NumTpdo_g,TimePdos_g).
Stat_CobIdMismatch(e) is the registered inequality of the copies. Err_CobId pulses in the cycle in which an
entry becomes unequal (DS-CP-02). An entry that is not usable matches no received frame, and a transmit request of its
object completes as aborted. A change of the configuration takes effect one cycle later.
3. Receive filter (DS-1)¶
One filter per bus classifies the frame of LinkRx_*(b) in the cycle of LinkRx_Valid(b). A frame qualifies only
when it is a data frame (Rtr = '0') with an 11-bit identifier (Ide = '0') and Nmt_NodeIdValid is '1'
(DS-RX-02, DS-RX-07). The first match in this order wins:
| Order | Identifier | Class | Further condition |
|---|---|---|---|
| 1 | 000h | NMT message | DLC 2 and byte 1 = Nmt_NodeId or 0; another DLC: protocol error; another node: discarded (DS-RX-03) |
| 2 | Entry 0 | SYNC | - |
| 3 | Entry 11 | Master heartbeat | - |
| 4 | 600h + Nmt_NodeId |
SDO request | SdoServer_g = true |
| 5 | Entries 2 to 5 | Receive PDO 1 to 4 | - |
| 6 | Entry 1 | Spacecraft Time PDO | TimePdos_g = true |
The identifier is bits 28 to 18 of LinkRx_Id. Bytes beyond the DLC are 0 (partner behaviour of olo_intf_can).
The order only matters for a configuration that gives two objects the same identifier, which ocan_od rejects for
restricted COB-IDs (6.10b).
4. Bus gate (DS-2)¶
The gate passes the classified frame of the active bus (Red_ActiveBus) to the protocol outputs and applies the
service enables (DS-RX-06): SDO requests with Nmt_EnaSdo, receive PDOs and the Spacecraft Time PDO with
Nmt_EnaPdo, SYNC with Nmt_EnaSync. NMT messages and master heartbeats are always passed. The NMT messages and
master heartbeats of both buses go to ocan_redundancy in the same cycle, each on its bus index (DS-BG-02).
Held NMT message (DS-BG-03, DS-BG-04):
| Condition | Action |
|---|---|
Red_Selecting = '1' and an NMT message on the inactive bus, none on the active bus in the same cycle |
Hold := '1' with the command specifier and the bus. From this cycle on, no frame of either bus reaches the protocol outputs (the per-bus events to ocan_redundancy continue) |
Hold = '1' and Red_ActiveBus = the held bus |
RxNmt_Valid with the held command specifier, Hold := '0' |
Hold = '1', Red_Selecting = '0' and Red_ActiveBus /= the held bus |
Hold := '0' without an event |
| NMT messages on both buses in the same cycle | The message of the active bus is passed; the other is not held |
The protocol outputs are registered: an event follows LinkRx_Valid by one clock cycle for every object and both
buses (DS-RX-05). The held NMT message is the exception; ocan_redundancy changes the active bus within a few cycles.
5. Transmit arbitration (DS-3)¶
Sources and their requester bits at olo_base_arb_rr (Width_g = 7; the left-most bit is served first):
| Bit | Source | Identifier | Service enable |
|---|---|---|---|
| 6 to 3 | Transmit PDO 1 to 4 | Entries 6 to 9 | Nmt_EnaPdo |
| 2 | Local Time PDO | Entry 10 | Nmt_EnaPdo |
| 1 | SDO reply | 580h + Nmt_NodeId |
Nmt_EnaSdo |
| 0 | NMT error control (boot-up, heartbeat) | 700h + Nmt_NodeId |
always |
- Reject path. A request whose service enable is clear, whose entry is not usable or that comes while
Nmt_NodeIdValidis '0' does not reach the arbiter. It is answered in the next cycle withReadyandAborted(DS-TX-04). - Arbitration. The other valid requests form
In_Req.olo_base_arb_rrgrants the first requester after the last granted one, in the order of the table (DS-TX-01). A pending source therefore waits for at most one frame of each other source (DS-TX-06). - Frame register. The register holds one frame (owner, identifier, DLC, eight data bytes).
| State | LinkTx_Valid |
Exit |
|---|---|---|
Idle_s |
'0' | Grant while LinkTx_Ready is '1' (DS-TX-08): the frame of the granted source is registered, Ready of that source, Out_Ready of the arbiter; to Send_s |
Send_s |
'1' | LinkTx_Ready = '1': to Wait_s. LinkTx_Stopped = '1', the service enable of the owner cleared or the NODE-ID invalid: Aborted to the owner, to Idle_s (the link has not taken the frame). During a bus switch the frame waits (DS-TX-08) |
Wait_s |
'0' | LinkTx_Done: Done to the owner; LinkTx_Aborted: Aborted to the owner; LinkTx_Ready = '1' without a completion event: Aborted to the owner (DS-TX-07); to Idle_s. The service enable of the owner cleared or the NODE-ID invalid: LinkTx_Abort (once) |
The when others branch leads to Idle_s. The completion events go to the owner of the frame only (DS-TX-03).
Interface rule. A source is not granted in the cycle of its own completion event: its requester bit is held
at '0' while Done or Aborted of that source is '1'. A request of that source waits one clock cycle in this
case. At every transmit port Ready together with Aborted is therefore the reject path only, and Ready never
comes together with Done. A protocol block that stops waiting for a taken frame (ocan_nmt at a reset
communication or a time-out) may request again at once; the late completion of the old frame cannot be taken for
the completion of the new request. The other protocol blocks rely on the same rule.
The frames are data frames with an 11-bit identifier; ocan_core ties Tx_Ide and Tx_Rtr of ocan_link to '0'.
5.1 Completion invariant of the link (DS-TX-07)¶
DS-TX-07 relies on this property of ocan_link and olo_intf_can: from the cycle after the link has taken a frame
until the cycle of its completion event, LinkTx_Ready is '0'. A LinkTx_Ready = '1' in Wait_s without
LinkTx_Done or LinkTx_Aborted therefore means that the link holds no frame of the dispatch, and the frame is
completed as aborted. The line numbers refer to olo_intf_can of Open Logic 4.7.0-ft.11 and to ocan_link of this
repository.
- olo_intf_can.
TxPendingis set only at the take (line 327:Tx_Valid= '1' andTxPending= '0'). Every assignment that clears it outsideRstsets the completion flag in the same branch: lines 242 and 244 (a failed attempt of an aborted frame), 340 and 342 (abort of a frame that is not on the bus), 470 and 472 (lost arbitration of an aborted frame), 707 and 708 (sent), 1004 and 1006 (aborted frame dropped).Tx_Readyisnot TxPending, andTx_DoneandTx_Abortedare registers of the same cycle (lines 1017 to 1020), soTx_Readyrises exactly in the cycle of the completion event. Bus off keeps the frame (lines 247 to 252, LK-TX-03):Tx_Readystays '0' until the recovery. - ocan_link, the take.
Tx_ReadyisTx_Readyof the controller of the active bus only inRun_swhile that controller is not stopped (line 283);Tx_Validreaches that controller under the same condition (lines 273 and 274), and the abort request of the dispatch is never '1' inSend_s. Every cycle withLinkTx_ReadyandLinkTx_Validat '1' is therefore a take by the controller of the active bus. - ocan_link, the controller of the active bus. It changes in two places only. From
Abort_stoSwitch_sit changes after itsTx_Readyis '1' (lines 325 to 328), in or after the cycle of the completion event. FromDisabled_stoRun_s(lines 314 to 316) the frame was aborted in the cycle inDisabled_s(line 278) and, with the controller disabled (lines 217 and 229), dropped byolo_intf_canat the same clock edge (its lines 335 to 342 and 983 to 1006): the completion event comes at the earliest in the first cycle inRun_s, together with the firstLinkTx_Ready, and the dispatch takes the event first. - ocan_link, a stop. A stopped controller gives
LinkTx_Ready= '0' (line 283); its frame is aborted and dropped one clock edge later, with its completion event (lines 278 and 229). - ocan_link, the events. The completion events of both controllers are combined (lines 288 to 290). The controller that is not the one of the active bus never holds a frame, since only that one takes a frame and it changes only after the completion of its frame.
- Frames back to back. The next take needs
Idle_s, a grant andSend_s, at least two clock edges after the completion event, so aLinkTx_Readyof the next frame cannot fall into theWait_sof the previous one. - Precondition.
ocan_linkandocan_dispatchshareRst. A reset of the link alone drops a frame without a completion event (olo_intf_canline 1072); DS-TX-07 then completes it as aborted.
5.2 Upsets¶
- An upset of
TxStatefromIdle_sorSend_stoWait_s, or a lost completion event, ends by DS-TX-07 in the cycle after the link is ready. - An upset of
TxStatefromIdle_stoSend_ssends the last frame again (identifier, DLC and data are kept) and reportsDoneto its owner. Covered by design review; the TMR of the synthesis tool (protection scope of the user guide). - An upset of
Holdpasses the last held NMT message once whenHoldBusis the active bus. Covered by design review. - An upset of
OwnerinWait_ssends the completion event to another source; the owner recovers by its own completion time-out (NM-HB-08, TM-TX-07), and a source ignores a completion event that it does not wait for.
6. Ports of ocan_dispatch¶
| Signal | Direction | Width | Description |
|---|---|---|---|
Clk, Rst |
In | 1 | Clock and synchronous high-active reset |
LinkRx_Valid |
In | 2 | Frame events of bus A (0) and bus B (1) from ocan_link |
LinkRx_Id, LinkRx_Ide, LinkRx_Rtr, LinkRx_Dlc, LinkRx_Data |
In | 58, 2, 2, 8, 128 | Frame fields per bus, as at ocan_link |
LinkTx_Valid, LinkTx_Ready |
Out, In | 1 | Frame to send to ocan_link |
LinkTx_Id, LinkTx_Dlc, LinkTx_Data |
Out | 29, 4, 64 | Identifier in bits 28 to 18 (bits 17 to 0 are 0), DLC, data |
LinkTx_Abort |
Out | 1 | Pulse: abort the pending frame |
LinkTx_Done, LinkTx_Aborted |
In | 1 | Completion events of ocan_link |
LinkTx_Stopped |
In | 1 | The controller of the active bus is stopped by its dominant monitor (Tx_Stopped of ocan_link) |
Red_ActiveBus, Red_Selecting |
In | 1 | Active bus and bus selection process from ocan_redundancy |
Nmt_NodeId, Nmt_NodeIdValid |
In | 7, 1 | NODE-ID and its validity from ocan_nmt |
Nmt_EnaSdo, Nmt_EnaPdo, Nmt_EnaSync |
In | 1 | Service enables from ocan_nmt |
Cfg_CobId, Cfg_CobIdCopy |
In | 144 | Two copies of the COB-ID table (section 2) from ocan_od |
RxNmt_Valid, RxNmt_Cs |
Out | 1, 8 | NMT message to ocan_nmt (command specifier) |
RxSync_Valid, RxSync_Dlc, RxSync_Data |
Out | 1, 4, 8 | SYNC to ocan_pdo and ocan_time (counter byte) |
RxRpdo_Valid, RxRpdo_Num, RxRpdo_Dlc, RxRpdo_Data |
Out | 1, 2, 4, 64 | Receive PDO 1 to 4 (number 0 to 3) to ocan_pdo |
RxTime_Valid, RxTime_Dlc, RxTime_Data |
Out | 1, 4, 64 | Spacecraft Time PDO to ocan_time |
RxSdo_Valid, RxSdo_Dlc, RxSdo_Data |
Out | 1, 4, 64 | SDO request to ocan_sdo |
RxRed_NmtValid, RxRed_HbValid |
Out | 2 | Per bus: NMT message, master heartbeat (to ocan_redundancy) |
RxRed_HbDlc, RxRed_HbState |
Out | 8, 16 | Per bus: DLC and state byte of the master heartbeat |
TxTpdo_Valid, TxTpdo_Ready |
In, Out | 4 | Transmit PDO 1 to 4 requests from ocan_pdo |
TxTpdo_Dlc, TxTpdo_Data |
In | 16, 256 | Per transmit PDO: DLC and data |
TxTpdo_Done, TxTpdo_Aborted |
Out | 4 | Per transmit PDO: completion |
TxTime_Valid, TxTime_Ready, TxTime_Dlc, TxTime_Data, TxTime_Done, TxTime_Aborted |
In, Out, In, In, Out, Out | 1, 1, 4, 64, 1, 1 | Local Time PDO from ocan_time |
TxSdo_Valid, TxSdo_Ready, TxSdo_Dlc, TxSdo_Data, TxSdo_Done, TxSdo_Aborted |
In, Out, In, In, Out, Out | 1, 1, 4, 64, 1, 1 | SDO reply from ocan_sdo |
TxNmt_Valid, TxNmt_Ready, TxNmt_Data, TxNmt_Done, TxNmt_Aborted |
In, Out, In, Out, Out | 1, 1, 8, 1, 1 | NMT error control (boot-up, heartbeat; DLC 1) from ocan_nmt |
Err_Protocol |
Out | 1 | Event: NMT frame with a DLC other than 2 |
Err_CobId |
Out | 1 | Event: a COB-ID entry became unequal |
Stat_CobIdMismatch |
Out | 12 | Per entry: the copies differ |
Byte 0 of every data field is in the top byte (bits 63 to 56), as at olo_intf_can.
7. Configuration parameters¶
| Generic | Default | Range | Description |
|---|---|---|---|
NumRpdo_g |
4 | 0 to 4 | Receive PDOs; entries above it are not usable |
NumTpdo_g |
4 | 0 to 4 | Transmit PDOs; requests of others are rejected |
TimePdos_g |
true | true, false | Entries 1 and 10 |
SdoServer_g |
true | true, false | SDO requests classified and SDO replies served |
8. Timing and behaviour¶
| Operation | Duration |
|---|---|
LinkRx_Valid to a protocol output or a per-bus event |
1 clock cycle |
Held NMT message to RxNmt_Valid |
1 clock cycle after Red_ActiveBus has changed to its bus |
Request to LinkTx_Valid (no frame pending) |
1 clock cycle (grant and frame register in the cycle of the request) |
Completion of the link to Done or Aborted of the owner |
1 clock cycle |
Rejected request to Ready and Aborted |
1 clock cycle |
LinkTx_Ready in Wait_s without a completion event to Aborted of the owner |
1 clock cycle |
LinkTx_Stopped in Send_s to Aborted of the owner |
1 clock cycle |
LinkTx_Ready enters Out_Ready of the arbiter and the Ready of the sources, so a combinational path runs from
the registers of ocan_link and olo_intf_can through the arbiter to the Ready of the protocol blocks. It has no
loop: the Valid of the protocol blocks and LinkTx_Valid are registers. A system that fails timing on this path
needs a register stage there.