Skip to content

ocan_nmt: Verification Report

1. Test results

Run with GHDL 6.0.0 (mcode), VUnit 5.0.0.dev7 and UVVM 2026.02.14: python run.py "*ocan_nmt*".

Testbench Test cases Runs (test case and configuration) Passed
ocan_nmt_tb 18 18 18
ocan_nmt_net_tb 3 3 3

The configurations are those of section 2 of the verification plan: TC-NM-13 runs in the configuration minimal, every other test case in default. In every cycle of the direct testbench the reference model predicted Stat_State, the service enables, Node_IdValid, Node_Id, the reset and error events (also Err_TxTimeout), Tx_Valid and Tx_Data, and no output differed from it. The responder of the direct testbench answers like ocan_dispatch: one taken frame at a time and no Tx_Ready in the cycle of a completion event. The network testbench runs ocan_nmt with ocan_dispatch and ocan_link on the CAN network model of tb/.

QuestaSim (Questa Pro Microchip Edition 2024.3): the same tests pass in the regression without code coverage (python run.py --questa -p 1) and with it (python run.py --questa --coverage -p 1); the coverage is in docs/coverage.md.

2. Measured values

Item Value
Reset to Reset_App, Reset_Comm and the boot-up request Cycles 2, 3 and 4 after the release of Rst (TC-NM-01)
NMT message to the new state and the service enables 1 clock cycle (every check of the direct testbench)
Heartbeat period P ticks exactly for P = 1, 2, 7, 1000 and 65535 (TC-NM-09)
First heartbeat after a restart, P = 3, tick every 16 cycles 47 cycles after a restart one cycle after a tick, 33 cycles one cycle before a tick, 48 cycles in the cycle of a tick: between P - 1 and P ticks (TC-NM-09)
Upset of a NODE-ID copy to Node_IdValid = '0' and Err_NodeId Same cycle; Reset_Comm in the next cycle (TC-NM-04, all 14 bits in all three states)
Heartbeats on the bus at P = 2 ms 2 ms apart within the bus timing of the frames (TC-NM-14)
Boot-up message without an acknowledge Repeated by the link for 10 ms, one request only, no heartbeat, the enables cleared; completed when a node acknowledged (TC-NM-15)
Taken request without completion to Err_TxTimeout 255 to 256 ticks for a heartbeat (TC-NM-20); for a boot-up message within 256 ticks, and the boot-up message is requested again in the cycle of the event
Reset communication while a taken heartbeat is awaited Boot-up request right after the sample (TC-NM-20); on the bus the boot-up message follows the heartbeat, and the enables return only after it (TC-NM-21)

3. Generic ranges

Generic Declared range Simulated Synthesised (lint/synth_check.py)
MinimalSet_g true, false both both

The producer heartbeat time is an input; its bounds 0, 1 and 65535 are simulated (TC-NM-09, TC-NM-10). Every NODE-ID 1 to 127 is simulated (TC-NM-02).

4. Negative tests and mutations

Every checker of the plan has a negative test (verification plan, section 5). In addition, 32 deliberate faults of ocan_nmt and one of ocan_dispatch were each simulated with the tests that must detect them. Every fault but one made a test fail:

Fault Detected by
No complement check of the NODE-ID code TC-NM-03
NODE-ID 0 accepted TC-NM-03
Node_IdValid without the compare of the copies TC-NM-04
Node_IdValid without the state (valid in the Initialisation) TC-NM-03
Node_IdValid in WaitId_s TC-NM-03
No reset communication at unequal copies TC-NM-04
Err_NodeId one cycle late TC-NM-04
Service enables not blocked by the boot-up message TC-NM-01
PDO enable in Pre-operational TC-NM-01, TC-NM-05
Reset node without the reset application sub-state TC-NM-05
No error event for an unknown command specifier TC-NM-06
Minimal set: NMT commands executed TC-NM-13
Request of ocan_redundancy evaluated before the command TC-NM-08
Heartbeat period P + 1 ticks TC-NM-09
No heartbeat at once after P changes from 0 TC-NM-10
No heartbeat at a bus switch TC-NM-10
Heartbeat byte with the state of the current cycle instead of the next TC-NM-19
Heartbeat requested while a request is pending TC-NM-11
Boot-up message not deferred behind a pending heartbeat TC-NM-11
Reject path not taken as a completion TC-NM-01, TC-NM-12
Aborted boot-up message not repeated TC-NM-12, TC-NM-17
Repetition only with P /= 0 TC-NM-12, TC-NM-17
Repetition not ended by a direct boot-up request TC-NM-16
Repetition not ended by a deferred boot-up request TC-NM-16
Abort in the cycle of a bus switch not counted for it TC-NM-17
Deferred boot-up request in the cycle of a reset command TC-NM-18
No completion time-out TC-NM-20
No boot-up request after the time-out of a boot-up message TC-NM-20
Wait not ended at a reset communication TC-NM-20
Minimal set: no return to Operational at the end of the bus selection TC-NM-13
NODE-ID sampled in every cycle of WaitId_s instead of at the tick TC-NM-03
ocan_dispatch: grant in the cycle of the own completion event TC-NM-21, and TC-DS-15 of ocan_dispatch; each alone
Heartbeat compare HbCnt = P - 1 instead of >= P - 1 Not detected; covered by design review

The compare with >= differs from = only when HbCnt is above P - 1, which needs an upset of the counter that the ports cannot inject (verification plan, section 7). The compare is kept for the recovery from such an upset and is covered by design review, as the when others recovery of both state machines is.

The direct bench answers the handshake with a responder, so the fault of ocan_dispatch is detected in the network bench, where ocan_dispatch is the real block: without the guard the completion of the awaited heartbeat is taken for the boot-up message, and the enables return before the boot-up message is on the bus.

The fault "repetition not ended by a direct boot-up request" was first not detected: TC-NM-16 ended the old request only after the new boot-up request had been deferred, where the deferred request clears the repetition. A third run now ends the old request through the reject path in the cycle of the reset communication, in which the new boot-up message is requested at once, and detects the fault.

The fault "heartbeat requested while a request is pending" was first not detected: TC-NM-11 held Tx_Ready, so the repeated request carried the same byte in TxReq_s. TC-NM-11 now also holds the completion after Tx_Ready for 3 P, where a repeated request is a second Tx_Valid, and detects the fault.

5. Summary

All 21 test cases pass in all 21 runs; every requirement of the specification is covered by the verification plan. VSG reports no errors and no warnings, and the GHDL synthesis of both configurations has no inferred latch.