ocan_time: Verification Report¶
1. Test results¶
Run with GHDL 6.0.0 (mcode), VUnit 5.0.0.dev7 and UVVM 2026.02.14: python run.py "*ocan_time*".
| Testbench | Test cases | Runs (test case and configuration) | Passed |
|---|---|---|---|
ocan_time_tb |
19 | 121 | 121 |
ocan_time_net_tb |
1 | 1 | 1 |
The configurations are those of section 2 of the verification plan: TC-TM-01 runs in every
configuration of the direct bench (default, f40m, f1m, fmax, fine0 to fine23), TC-TM-02 in f40m and
f1m, TC-TM-06 and TC-TM-14 in default and f1m, TC-TM-03, TC-TM-07 and TC-TM-11 in default and fine0 to
fine23, every other direct test case in default. In every cycle of the direct testbench the reference model
predicted Time_Coarse, Time_Fine, Stat_Scet, Stat_TimeSet, the events, Tx_Valid and, while it is '1',
Tx_Dlc and Tx_Data, and no output differed from it. The model computes the local time in closed form from the
specification, the last setting plus floor(n * 2^F / f), and is independent of the accumulator of the architecture.
The network testbench runs ocan_time with ocan_dispatch and ocan_link on the CAN network model of tb/.
QuestaSim (Questa Pro Microchip Edition 2024.3): the same tests pass in the regression without code coverage
(python run.py --questa -p 1) and with it (python run.py --questa --coverage -p 1); the coverage is in
docs/coverage.md.
2. Measured values¶
| Item | Value |
|---|---|
| Advance of the local time | Equal to floor(n x 2^F / f) in every cycle of every run, for f = 1 MHz, 40 MHz, 100 MHz and 2^31 - 1 Hz and every F from 0 to 24 (TC-TM-01); over 2^24 + 12345 cycles at 40 MHz and 1 MHz without a deviation (TC-TM-02) |
Rx_SyncValid to the sample and Evt_Sync |
The local time of the cycle of the event, on every phase of the accumulator at 100 MHz and 1 MHz: in the Local Time PDO of type 1 for 66 SYNCs (TC-TM-06) and as the last sample of types 254 and 255 for 66 SYNCs, also with the request in the cycle of the SYNC (TC-TM-14); Evt_Sync 1 clock cycle later (TC-TM-06) |
Rx_TimeValid (basic protocol) and Cfg_SetValid to the setting |
The set value 1 clock cycle later (TC-TM-05, TC-TM-08) |
Rx_TimeValid (high-resolution protocol) to the setting |
2 clock cycles; from then on the local time is the SCET at the sample plus floor(n x 2^F / f), for 0 to 10^6 cycles between the sample and the PDO (TC-TM-09, TC-TM-20) |
Sampled SYNC or Req_Valid to Tx_Valid |
1 clock cycle (every check of the direct testbench) |
Taken Local Time PDO without completion to Err_TxTimeout |
At the 256th tick after the frame was taken, in the cycle that the reference model predicts; no repetition (TC-TM-19) |
Last bit of the SYNC frame, as the transmitter M1 logs it, to Evt_Sync, 40 MHz, 1 Mbit/s |
-837.5 ns on bus A and on bus B. Negative, since a receiver takes a frame at the last but one bit of the end of frame, one bit time before the transmitter logs it (TC-TM-18) |
3. Generic ranges¶
| Generic | Declared range | Simulated | Synthesised (lint/synth_check.py) |
|---|---|---|---|
ClkFrequency_g |
1000000 to 2^31 - 1 | 1000000, 40000000, 100000000, 2147483647 | 1000000, 100000000, 2147483647 |
FineBits_g |
0 to 24 | every value from 0 to 24 | 0, 1, 23, 24; 0 at 1000000 and at 2147483647 |
4. Negative tests and mutations¶
Every checker of the plan has a negative test (verification plan, section 5). In addition, 33 deliberate faults of the RTL were each simulated with the tests that must detect them. In the first run 30 made a test fail. Two were not detected, by gaps of the bench described below; TC-TM-05 and TC-TM-14 were extended, and both faults, simulated again with the extended bench, make a test fail. The extension adds stimuli and checks to these two test cases only and the RTL is unchanged, so the 30 detections of the first run stand. One fault changes the behaviour only after an upset that the ports cannot inject and is covered by design review:
| Fault | Detected by |
|---|---|
Advance by Q_c + 2 at a carry |
TC-TM-01 |
| Carry only above f | TC-TM-01 |
Acc not cleared at a basic setting |
TC-TM-08 |
Acc not cleared at a write |
TC-TM-05 |
Elap not one cycle ahead |
TC-TM-09 |
Elap not restarted at a SYNC |
TC-TM-09 |
| High-resolution load without the accumulator | TC-TM-09 |
No Evt_Set at the high-resolution load |
TC-TM-09 |
| SYNC with DLC 2 sampled | TC-TM-06 |
| Sample one cycle late | TC-TM-14 |
| No check of a sample since the reset (TM-RX-05) | TC-TM-04 |
| A SYNC in the cycle of the PDO not taken first | TC-TM-20 |
| Fine bytes of the PDO in the wrong order | TC-TM-07 |
| Fine time cut to its lower bits | TC-TM-07 |
| PDO with DLC 6 processed | TC-TM-07 |
| Types 241 to 253 processed | TC-TM-10 |
| A high-resolution load in the cycle of a write not cancelled | TC-TM-05 |
| Frame bytes in the wrong order | TC-TM-11 |
| Frame with DLC 8 | TC-TM-11 |
| SYNC count one too high | TC-TM-12 |
| No restart of the count at a type change | TC-TM-12, TC-TM-20 |
| No restart of the count at a reset communication | TC-TM-12, TC-TM-13 |
| Type 0: a request in the cycle of a SYNC taken at once | TC-TM-20 |
| Type 254: the time of the request instead of the sample | TC-TM-14 |
| A second request while one is pending | TC-TM-16 |
No Err_TxBusy |
TC-TM-16 |
| Reject path not taken as a completion | TC-TM-16 |
| A request in the cycle of a completion not made | TC-TM-16 |
| No completion time-out | TC-TM-19 |
| Time-out after 255 ticks | TC-TM-19 |
No Err_TxTimeout |
TC-TM-19 |
| No set flag at a write | TC-TM-05 |
| SYNC count compared with = | Not detected; covered by design review |
SyncCnt exceeds T - 1 only after an upset, since a change of the type and a reset communication restart the count
(verification plan, section 7).
The two faults that the first run did not detect were gaps of the bench, not of the RTL. "Sample one cycle late":
the sample is sent only in a Local Time PDO of type 254 or 255 in the high-resolution protocol (TM-TX-04); a frame
of types 0 to 240 carries the local time of the cycle of its SYNC directly. TC-TM-14 checked one such sample for
each type, and at 100 MHz with 24 fine bits the local time advances in about one cycle of six, so both samples fell
on cycles without an advance. TC-TM-14 now checks 64 more samples at random distances and also runs in f1m, where
the local time advances in every cycle; TC-TM-06 was extended in the same way for the frames of type 1. "A
high-resolution load in the cycle of a write not cancelled": the tests wrote in the second cycle of a
high-resolution setting, not in the cycle of its PDO; TC-TM-05 now does.
5. Summary¶
All 20 test cases pass in all 122 runs; every requirement of the specification is covered by the verification plan.
VSG reports no errors and no warnings, and the GHDL synthesis of the eight configurations of lint/synth_check.py
has no inferred latch.