ocan_od: Verification Report

1. Test results

Run with GHDL 6.0.0 (mcode), VUnit 5.0.0.dev7 and UVVM 2026.02.14: python run.py "*ocan_od*".

Testbench Test cases Runs (test case and configuration) Passed
ocan_od_tb 20 36 36

The configurations are those of section 2 of the verification plan: every test case runs in default; TC-OD-01 and TC-OD-15 also in values; TC-OD-02 in rpdo0 to rpdo3, tpdo0 to tpdo3 and notime; TC-OD-12 and TC-OD-13 also in rpdo1 and notime; TC-OD-18 in unconnected; TC-OD-19 in minimal and minimal_time. In every cycle the reference model predicted the answer of the access interface (Rsp_Valid, Rsp_Data, Rsp_Len, Rsp_Abort), Acc_Ready, every output to the blocks (both copies of the COB-ID table, the heartbeat times, Bdefault, Ttoggle, Ntoggle, the transmission types, the Ctoggle and Local SCET Set events), the error register, both events and the request of the application port, and no output differed from it. The model holds table 1 of the specification and the write rules, and keeps the two copies of the protected parameters as the specification defines them (OD-PR-01 to OD-PR-03).

TC-OD-21, the negative elaboration of OD-MS-03, OD-MS-05 and of the generic checks, runs in lint/synth_check.py (section 3).

QuestaSim (Questa Pro Microchip Edition 2024.3): the same tests pass in the regression without code coverage (python run.py --questa -p 1) and with it (python run.py --questa --coverage -p 1); the coverage is in docs/coverage.md.

2. Measured values

Item Value
Access to an object of table 1 to the answer 1 clock cycle (every access of every test)
Accepted write to the new value at the outputs 1 clock cycle (TC-OD-09)
Access to an object of the user logic to App_ReqValid 1 clock cycle (TC-OD-16)
Response of the user logic to the answer 1 clock cycle, for responses 0 to 1000 cycles after the request (TC-OD-16)
Unconnected application port: access to the answer 0602 0000h 3 clock cycles (TC-OD-18)
No response of the user logic 0800 0000h and Err_AppTimeout at the 256th tick after the access; a request without App_ReqReady withdrawn; a late response ignored (TC-OD-17)
Copies of a parameter that disagree The power-on value at the output and Err_ParamCopy in the cycle of the disagreement, both copies repaired in the next cycle, bit 7 of 1001h until the next reset communication, for every bit of both copies (TC-OD-13)
Copies of a COB-ID entry that disagree Both copies at Cfg_CobId and Cfg_CobIdCopy until a write or a reset communication, bit 0 of 1001h meanwhile, for every bit of both copies (TC-OD-12)
Bits of absent PDOs No effect: no event, the entries of the COB-ID table constant 0 (TC-OD-12, TC-OD-13 in rpdo1 and notime)

3. Generic ranges

Generic Declared range Simulated Synthesised (lint/synth_check.py)
MinimalSet_g true, false both both
NumRpdo_g, NumTpdo_g 0 to 4; at most 3 with MinimalSet_g and TimePdos_g 0 to 4; 3 in minimal_time 0 to 4; 4 with MinimalSet_g and TimePdos_g rejected (TC-OD-21)
TimePdos_g true, false both both
32-bit values (DeviceType_g, identity) 32 bits 0 and values with bit 31 set (values) 0
ProducerHbTime_g, MasterHbTime_g 0 to 65535 1000, 1500, 0, 65535 the defaults, 65535 and 0
MasterNodeId_g 0 to 127 1, 127 1, 127
Bdefault_g 0, 1 both both
Ttoggle_g, Ntoggle_g 0 to 255 1, 3, 0, 255 the defaults, 255 and 0
RpdoType_g, TpdoType_g, SctType_g, LtpType_g 0 to 240, 254, 255 254, 0, 240, 255, 1 254, 255, 0, 240; 241, 253 and 256 rejected (TC-OD-21)
SctCobId_g, LtpCobId_g 0 to 2047, not restricted, not free, not equal; not 0 with MinimalSet_g and TimePdos_g 0, 0F0h, 1F5h 0, 0F0h, 1F5h, 4FFh, 500h; 581h, 7FFh, two equal values and 0 with MinimalSet_g and TimePdos_g rejected (TC-OD-21)

4. Negative tests and mutations

Every checker of the plan has a negative test (verification plan, section 5). In addition, 52 deliberate faults of the RTL were each simulated with the tests that must detect them, and every one made a test fail:

Fault Detected by
No object check TC-OD-02
No sub-index check TC-OD-02
Write of a read-only object taken TC-OD-03
Read of a write-only object taken TC-OD-03
Too many bytes taken TC-OD-04
Too few bytes taken TC-OD-04
Number of bytes 0 refused TC-OD-04
COB-IDs written outside Pre-operational TC-OD-05
Parameters written in Stopped and Initialisation TC-OD-05
No lock of a valid COB-ID TC-OD-06
Lock rule from copy A only TC-OD-12
Remote frames allowed TC-OD-06
29-bit identifiers allowed TC-OD-06
Bits 28 to 11 not checked TC-OD-06
Restricted identifiers of PDOs allowed TC-OD-06
Restricted range 6E0h to 6FFh from 6E1h TC-OD-06
Restricted range up to 07Eh TC-OD-06
Restricted range 701h to 77Fh from 702h TC-OD-06
No duplicate check TC-OD-06
SYNC producer allowed TC-OD-06
Transmission type 241 taken TC-OD-07
Transmission type 253 taken TC-OD-07
Reserved bits of 1016h taken TC-OD-08
NODE-ID 128 in 1016h taken TC-OD-08
Bdefault 2 taken TC-OD-08
An access in the cycle of a reset takes effect TC-OD-11
The update of Bdefault wins over a write TC-OD-11
No repair of 1017h TC-OD-13
Copy A at the output while the copies disagree TC-OD-13
No compare of the transmission types TC-OD-13
Copies of absent transmission types compared TC-OD-13
Latch not set TC-OD-13
Latch not cleared by a reset communication TC-OD-13
One copy at both COB-ID outputs TC-OD-12
Absent COB-ID entries not constant TC-OD-02
Error register bit 0 without the COB-ID disagreement TC-OD-12, TC-OD-14
Error register bit 4 only at bus off TC-OD-14
Bdefault not kept at a reset TC-OD-15
No reset of the communication profile area TC-OD-15
Identifiers without the NODE-ID TC-OD-09
Master heartbeat entry valid with NODE-ID 0 TC-OD-08
Time-out after 255 ticks TC-OD-17
No time-out of the application port TC-OD-17
A response taken while the request waits for ready TC-OD-16
A second access taken while a request is outstanding TC-OD-16
An outstanding request answered at a reset TC-OD-15
Accesses taken in the minimal set TC-OD-19
Test input without effect TC-OD-12
2002h returns the last Set value TC-OD-10
No Cfg_SetValid TC-OD-10
No Cfg_CtoggleValid TC-OD-08
Mapping of the Spacecraft Time PDO with 8 bits TC-OD-01

The first mutation run detected 50 of the faults. "An outstanding request answered at a reset" was a gap of the bench, not of the RTL: TC-OD-15 reset while no response was pending, where the fault has no effect. TC-OD-15 now also resets in the cycle of the response of the user logic, and the fault is detected. The RTL is unchanged since the first run, and the bench gained stimuli and checks only, so the 50 detections of that run stand.

The write whose number of bytes is not indicated (OD-IF-01, OD-WR-02) later changed the two length checks of the RTL and of the reference model and extended TC-OD-04, the only test that writes with the number 0. The three faults of the length checks, among them "Number of bytes 0 refused", ran again on the changed RTL and bench and were all detected. TC-OD-04 detects no other fault, and the other tests write with 1 to 8 bytes only, where both checks are unchanged, so the other detections stand.

The first regression run had five failures, all errors of the bench: an invalidation of a PDO that changed its identifier, which OD-WR-04 refuses, a leftover abort code of the responder and a race in reading an event counter. The RTL answered as the specification requires in each case.

5. Summary

All 20 test cases pass in all 36 runs, and TC-OD-21 passes in lint/synth_check.py; every requirement of the specification is covered by the verification plan. VSG reports no errors and no warnings, and the GHDL synthesis of the ten valid configurations of lint/synth_check.py has no inferred latch; the nineteen inconsistent ones are rejected with their messages.