ocan_core

Top level of OpenCAN: the slave node of ECSS-E-ST-50-15C with the eight blocks of the architecture, the reset synchroniser and the millisecond tick (CO-1 to CO-3), and the applicability of [CiA301] of clause 11.1.

Document Content
specification.md Requirements
architecture.md Reset and tick, connections of the blocks, configurations, ports
verification_plan.md Test cases
verification_report.md Results

The user guide describes the integration of the core.

Tests

python run.py "*ocan_core*"
python lint/synth_check.py
File Content
src/ocan_core.vhd The top level: the reset synchroniser, the millisecond tick, the eight blocks and their connections, the generic checks
tb/ocan_core_net_tb.vhd Network testbench: the model node M1 of the active bus as Redundancy Master, NMT master, SYNC and time producer, SDO client and peer of the PDOs, M2 for acknowledges and disturbing frames, models of the user logic at the PDO port and at the application port, checkers of the frames of the node in every test
tb/ocan_core_net_th.vhd Harness of the network testbench: the clock and ocan_core with the parameters of the verification plan on the CAN network model with two model nodes on each bus
tb/vunit_config.py The four configurations of the network testbench