ocan_link: Specification

1. Overview

ocan_link connects OpenCAN to the two buses of a redundant CAN network (ECSS-E-ST-50-15C clauses 5.4, 5.6 and 8.2). It contains the CAN 2.0B controller olo_intf_can of Open Logic once or twice, depending on the bus access architecture (D4 of the architecture). It switches the active bus on request, passes the received frames of each bus with a fixed latency and sends the frames of ocan_dispatch on the active bus. It also reports the error state and the error counters of every controller.

Block Entity Function
LK-1 ocan_link (olo_intf_can, one or two) CAN protocol, bit timing, fault confinement
LK-2 ocan_link Bus selector of the selective bus access: connects the controller to transceiver A or B
LK-3 ocan_link Bus switch sequencer: abort of a pending frame, disable, selection or mode change, enable
LK-4 ocan_link Receive path: frames of each bus as events with a fixed latency
LK-5 ocan_link Transmit path: one frame at a time to the controller of the active bus
LK-6 ocan_link Dominant monitor: releases a transmit output that stays dominant too long, per controller

ocan_link runs in one clock domain; the bus inputs pass the synchronisers of olo_intf_can (SyncTmr_g = true).

2. Requirements

2.1 Interfaces

ID Requirement ECSS
LK-IF-01 The link shall connect to bus A and bus B, each with a transmit output, a receive input and a transmit enable output for its transceiver; '1' on the transmit output and the receive input is the recessive level. 8.2.1a, 8.2.3a
LK-IF-02 The link shall take frames to send (identifier, IDE, RTR, DLC, eight data bytes) with a valid/ready handshake, take an abort request, and report the completion of each frame (sent or aborted) and every lost arbitration as events. 5.6.1a
LK-IF-03 The link shall pass every frame received on a bus (identifier, IDE, RTR, DLC, eight data bytes) as a one-cycle event of that bus, without back pressure. 5.6.1a, 8.2.2a
LK-IF-04 The link shall take the bit timing configuration (prescaler, PROP_SEG + PHASE_SEG1, PHASE_SEG2, SJW) as inputs common to all controllers. The configuration is applied while the link is disabled and is static while it is enabled. 5.4.3a, 5.4.3d
LK-IF-05 The link shall take an enable input, the requested active bus, a bus-off recovery request and, per controller, a re-enable request after a dominant timeout. 6.10f, 8.2.3a, 5.3.6b
LK-IF-06 The link shall provide the active bus and a busy indication while a bus switch is in progress. Per controller it shall provide the transmit and receive error counts, the fault confinement state (error active, error passive, bus off), the bus idle state, the error events (bit, stuff, CRC, form, acknowledgement), and the dominant timeout as an event and as a state; and, with the transmit handshake, the stop state of the controller of the active bus. 5.6.2a, 5.6.2b, 5.6.2c, 5.3.6b
LK-IF-07 The link shall have a fault injection test input per controller, inactive by default, that forces the transmit output of the controller dominant ahead of the dominant monitor, and a second one, inactive by default, that inverts the complement of the stop state of the controller (LK-DT-02). 5.3.6b

2.2 Bus access (LK-1, LK-2)

ID Requirement ECSS
LK-BA-01 With selective bus access (BusAccess_g = "Selective") the link shall have one olo_intf_can. The bus selector connects its transmit output and receive input to the active bus. The transmit output of the other bus shall be recessive and its transmit enable inactive. 8.2.1a, 8.2.3a
LK-BA-02 With parallel bus access (BusAccess_g = "Parallel") the link shall have one olo_intf_can per bus. The controller of the active bus runs in normal mode. The controller of the inactive bus runs in listen-only mode and the transmit enable of its bus is inactive. 8.2.1a, 8.2.2a
LK-BA-03 The transmit enable of the active bus shall be active while its controller is enabled in normal mode, and inactive otherwise. 8.2.3a
LK-BA-04 While the enable input is inactive, every controller shall be disabled, both transmit outputs recessive and both transmit enables inactive; no frame is passed or taken, and a frame pending at the disable is dropped and reported as aborted. 6.10f

2.3 Protocol and bit timing (LK-1)

ID Requirement ECSS
LK-PR-01 The CAN protocol shall be that of olo_intf_can: data and remote frames with standard (11-bit) and extended (29-bit) identifiers, bit stuffing, CRC, acknowledgement, error detection and signalling, and fault confinement. 5.6.1a, 5.6.2a
LK-PR-02 The bit rates 1 Mbit/s, 500 kbit/s, 250 kbit/s and 125 kbit/s shall be reachable through the bit timing configuration for every clock frequency f with f = r x P x Q for the bit rate r, a prescaler P of 1 to 1023 and Q of 8 to 25 time quanta per bit. 5.4.1a, 5.4.2a
LK-PR-03 The time quantum, the sample point and the resynchronization jump width (1 to min(4, PROP_SEG + PHASE_SEG1, PHASE_SEG2) time quanta) shall be configurable. 5.4.3a, 5.4.3d
LK-PR-04 The controllers shall synchronise on recessive-to-dominant edges only, and shall receive and send correctly with a far end whose bit time differs by the oscillator tolerance of the configured bit timing. 5.4.3e

2.4 Bus switch (LK-3)

ID Requirement ECSS
LK-BS-01 After the reset, and whenever the link is enabled, the active bus shall be the requested active bus. 8.3.2a
LK-BS-02 When the requested active bus differs from the active bus, the link shall switch the bus in this order. It requests the abort of a pending frame and waits until no frame is pending. It disables the controllers and changes the bus selector (selective) or exchanges the modes of the two controllers (parallel). It then enables the controllers and reports the new active bus. 8.2.3a
LK-BS-03 During a bus switch the link shall take no frame to send. After the switch a controller shall integrate on its bus (11 recessive bits) before it receives or sends. 8.2.3a
LK-BS-04 A frame pending at the start of a bus switch shall never be sent on the new bus. A frame that is on the bus when the abort is requested completes on the old bus as sent or aborted. 8.3.3e
LK-BS-05 A request that changes during a bus switch shall be taken when the switch has ended: the active bus then follows the latest request. 8.2.3a
LK-BS-06 The error counts and the fault confinement state of a controller shall be kept across a bus switch and while the controller is disabled. 5.6.2a, 5.6.2c

2.5 Receive path (LK-4)

ID Requirement ECSS
LK-RX-01 Every frame that a controller receives shall be passed as an event of the bus that the controller is connected to. The event follows the reception by olo_intf_can by a constant number of clock cycles, the same for both buses and both bus access architectures. 5.6.1a, 7.2.3k
LK-RX-02 With parallel bus access, frames received on both buses in the same clock cycle shall be passed in the same clock cycle, each as an event of its bus. 8.2.2a
LK-RX-03 A frame received on the inactive bus (parallel bus access, listen-only controller) shall be passed like a frame of the active bus. 8.2.2a

2.6 Transmit path (LK-5)

ID Requirement ECSS
LK-TX-01 A frame shall be taken only while the link is enabled, no bus switch is in progress and no frame is pending. The controller of the active bus sends it and retransmits it after an error or a lost arbitration until it is sent or aborted. 5.6.1a
LK-TX-02 An abort request shall drop a pending frame that is not on the bus at once. A frame that is on the bus shall complete: it is reported as sent after a successful attempt and dropped after a failed one. 5.6.1a
LK-TX-03 A bus-off controller shall keep its pending frame and send it after the bus-off recovery unless it is aborted. 5.6.2a

2.7 Fault confinement and status (LK-1)

ID Requirement ECSS
LK-FC-01 The link shall provide, per controller, the transmit error count, the receive error count and the fault confinement state (error active, error passive, bus off). The application can read them at any time without affecting the protocol. 5.6.2a, 5.6.2b, 5.6.2c
LK-FC-02 The link shall pass, per controller, the bit, stuff, CRC, form and acknowledgement error events. 5.6.2a
LK-FC-03 With AutoRecover_g = true a bus-off controller shall recover after 128 occurrences of 11 consecutive recessive bits; with AutoRecover_g = false this recovery shall start only after a recovery request. 5.6.2a

2.8 Dominant monitor (LK-6)

ID Requirement ECSS
LK-DT-01 When the transmit output of a controller has been dominant for more than DominantLimit_g bit times of the configured bit timing, the link shall set that transmit output recessive and its transmit enable inactive, disable the controller, abort its pending frame and raise the dominant timeout event. 5.3.6b
LK-DT-02 A controller stopped by a dominant timeout shall stay disabled, with its transmit output recessive, until its re-enable request or until the link is disabled and enabled again. The dominant timeout state is set while it is stopped. The stop state of each controller shall be held as a value and its complement. Values that are not complementary shall release the controller, so that a single upset does not stop it; a controller whose transmit output is still dominant is stopped again by LK-DT-01. 5.3.6b
LK-DT-03 While the controller of the active bus is stopped, the link shall take no frame to send. A bus switch shall remain possible; with parallel bus access the stopped controller does not take part in it until it is re-enabled. 5.3.6b, 8.2.3a
LK-DT-04 No dominant sequence that olo_intf_can drives in operation, including its reaction to bit errors during its own error flags, shall reach the limit at the default DominantLimit_g. 5.3.6b

3. Error conditions

Condition Detection Response
Bit, stuff, CRC, form or acknowledgement error LK-1 Error frame and error counts per the protocol; event per controller
Error passive, bus off LK-1 State per controller; a bus-off controller keeps its transmit output recessive until it has recovered
Bus stuck dominant or broken LK-1 (no bus idle, errors) A pending frame that never started is dropped at once on an abort; a bus switch completes
Request for the other bus during a bus switch LK-3 Taken after the running switch
Enable removed during a bus switch LK-3 Controllers disabled; the switch ends; on the next enable the active bus is the requested bus
Transmit output dominant for more than DominantLimit_g bit times (stuck controller, upset) LK-6 Transmit output recessive, transmit enable inactive, controller disabled, pending frame aborted, event and state until the re-enable request
Stop state and its complement not complementary (upset) LK-6 Controller released; stopped again by LK-DT-01 if its transmit output is still dominant

4. Configuration parameters

Generic Default Range Description
BusAccess_g "Selective" "Selective", "Parallel" Bus access architecture of clause 8.2 (D4)
SyncStages_g 2 2 to 4 Synchroniser stages of the bus inputs (olo_intf_can)
AutoRecover_g true true, false Automatic bus-off recovery, or recovery on request (olo_intf_can)
DominantLimit_g 32 13 to 1023 Limit of the dominant monitor in bit times (LK-DT-01); the default and the lower bound follow from section 5

The bit timing has no generic: it is set at runtime (LK-IF-04). SyncTmr_g of olo_intf_can is always true (family rule for synchronisers).

5. Partner behaviour: olo_intf_can

From the source and the documentation of olo_intf_can in [OLO] 4.7.0-ft.11:

  • Transmit. A frame is taken with Tx_Valid while Tx_Ready is '1' and stays pending until Tx_Done or Tx_Aborted. The controller retransmits it after an error or a lost arbitration (Tx_ArbLost); it has no transmit queue.
  • Abort. Tx_Abort drops a pending frame that is not on the bus at once (Tx_Aborted). A frame on the bus completes: Tx_Done on success, otherwise it is dropped instead of retransmitted.
  • Disable. Cfg_Enable = '0' keeps the transmit output recessive and stops the bit processing. A frame on the bus is cut, but a pending frame stays pending and is sent after the next enable, so the bus switch has to abort it first (LK-BS-02, LK-BS-04). After the enable the controller integrates (11 recessive bits). The error counts and the bus-off state are kept; disabling does not bypass the bus-off recovery.
  • Listen-only. No acknowledge, no error or overload flags, no transmission; a pending frame is not started; the error counts do not change; errors are pulsed. Cfg_ListenOnly is static while Cfg_Enable is '1'.
  • Receive. Rx_Valid is a one-cycle pulse after the last but one bit of the end of frame field, with no back pressure. Remote frames and frames with a data length code above 8 are output, the bytes beyond the data length are 0, and the controller does not output its own frames (except in loopback mode).
  • Bit timing. Cfg_Tseg1 is PROP_SEG + PHASE_SEG1; SJW is limited to min(4, Cfg_Tseg1, Cfg_Tseg2). Hard synchronisation at a recessive-to-dominant edge in bus idle, resynchronisation on recessive-to-dominant edges within a frame only.
  • Longest dominant sequences on Can_Tx. Without a fault the controller drives at most 6 consecutive dominant bits:

    • the bit stuffing limits a frame to 5;
    • an active error or overload flag has 6;
    • the bit before a flag is one that the controller drives recessive.

    On the bus, superposed error flags reach 12 dominant bits (Bosch 2.0, section 3.2.3). When the dominant bits of the controller do not reach its receive input, every flag bit is a bit error. The controller then restarts its active error flag (rules 4 and 5) and adds 8 to an error count each time, until the count reaches 128 and the flag becomes passive. That gives at most 16 active flags of one bit each after up to 5 dominant frame bits: 21 bits. The default limit of 32 bit times lies 11 bit times (about 50 %) above this sequence. The lower bound of 13 lies above the 12 bits of superposed error flags.

6. Interpretation of the standard

Clause Interpretation
5.4.1a, 5.4.2a The supported bit rates are those of the transceivers and of the device. The link reaches all four rates of the standard (LK-PR-02); which of them a device supports is set by its bit timing configuration
5.4.3b, 5.4.3c The calculation method and the choice of the bit timing are a system task: the integrator computes the values for the network, and the link accepts any valid setting. canBitTiming of Open Logic is an aid with its own criterion (smallest rate error); the user guide gives the formulas
5.4.3d olo_intf_can limits SJW also to PHASE_SEG2. Bosch 2.0 makes PHASE_SEG2 at least PHASE_SEG1, so every value that the clause allows is accepted
5.3.6a, 5.3.6b The inversion of the transmit bit for the RS-485 driver and its fail-safe mechanism belong to the board. The link keeps the transmit output of a disabled or inactive bus recessive and its transmit enable inactive. Its dominant monitor (LK-DT-01) is a second protection on the FPGA side against a controller that holds the bus dominant; it does not replace the mechanism of the board, which also covers the transceiver
5.6.2b The error active and error passive states are indicated together with bus off (LK-FC-01)
8.2.2a Read with the expanded information of Annex A.4.2: a node with parallel bus access accesses each bus through its own controller
8.2.3a The selection mechanism of the link is the requested active bus input. ocan_redundancy drives it; how the application selects the bus is specified there