Skip to content

ocan_redundancy: Verification Report

1. Test results

Run with GHDL 6.0.0 (mcode), VUnit 5.0.0.dev7 and UVVM 2026.02.14: python run.py "*ocan_redundancy*".

Testbench Test cases Runs (test case and configuration) Passed
ocan_redundancy_tb 21 24 24
ocan_redundancy_net_tb 4 6 6

The configurations are those of section 2 of the verification plan: TC-RM-01, TC-RM-14 and TC-RM-20 run in the configurations default and minimal, TC-RM-15 in minimal, every other direct test case in default; TC-RM-17 and TC-RM-19 run with selective and with parallel bus access, TC-RM-18 with parallel and TC-RM-25 with selective bus access. In every cycle of the direct testbench the reference model predicted Link_Bus, Stat_Selecting, Stat_Ctoggle, Stat_HbState, Stat_HbPresent, Nmt_PreopReq, Nmt_Switched, Upd_Valid with Upd_Bdefault and the three error events, and no output differed from it. The reference model is derived from the requirements of the specification and is independent of the state machine of the architecture (verification plan, section 1). Run against the RTL of the reviewed state before the corrections of RM-SL-01 and RM-SL-03 and of the compares, the same benches fail in 9 of 30 runs, among them by the comparison with the reference model in the random test TC-RM-14 and in TC-RM-20. The network testbench runs ocan_redundancy with ocan_nmt, ocan_dispatch and ocan_link on the CAN network model of tb/; TC-RM-25 injects one NMT message at the receive input of ocan_nmt (Rx_Valid, Rx_Cs) in the network harness, while ocan_link reports the switch; the modules stay the real ones.

QuestaSim (Questa Pro Microchip Edition 2024.3): the same tests pass in the regression without code coverage (python run.py --questa -p 1) and with it (python run.py --questa --coverage -p 1); the coverage is in docs/coverage.md.

2. Measured values

Item Value
Last master heartbeat to Err_HbMissing, T x C = 3 ticks of 16 cycles 48 cycles after a heartbeat one cycle after a tick, 34 cycles after a heartbeat one cycle before a tick (TC-RM-03)
Last master heartbeat to Err_HbMissing for (C, T) = (1, 1), (5, 3), (2, 255), (65535, 1) and T = 0 T x C ticks exactly, for a heartbeat one cycle after a tick (TC-RM-03)
Pre-operational to the first toggle after a missing heartbeat 1 clock cycle, for the NMT state reached after 0, 1 and 50 cycles and after 10 ticks of Initialisation (TC-RM-07)
End of the switch by the link to Nmt_Switched 1 clock cycle, for switch times of 1 and 400 cycles (TC-RM-07)
A toggle due while the node is Operational or Stopped Nmt_PreopReq at every expiry, T x C = 40 cycles apart; the toggle in the cycle after Pre-operational (TC-RM-20, also from Operational entered during the switch and in the minimal set)
C lowered from 10 to 3 six ticks after a master heartbeat The presence cleared at the next tick (TC-RM-22)
Err_HbMissing to Err_ToggleEnd with N = 0 1 clock cycle (TC-RM-08)
Toggle that waited for Pre-operational to the next toggle, T x C = 10 ticks of 4 cycles Between 38 and 41 cycles, (T x C - 1) x M + 2 to T x C x M + 1 (TC-RM-13)
Master heartbeat moved to bus B, T x C = 6 ms Bus selection process started by the missing heartbeat, bus B found with the next master heartbeat on it, Bdefault updated to bus B; the first heartbeat of the node on bus B less than 500 µs after the switch event (TC-RM-17, selective and parallel bus access)
Master on bus B during the start-up process, parallel bus access Process ended on bus B in less than 2 ms, before the first toggle, by a master heartbeat and by an NMT message (TC-RM-18)
Bus A stuck dominant or broken, master on bus B Bus B found and Bdefault updated (TC-RM-19)
An NMT Start of bus A delivered during the first switch (selective bus access) The node Operational on bus B; at the next expiry Pre-operational again, the toggle back to bus A, the process ended by the master heartbeat (TC-RM-25)
Both buses broken, Ntoggle = 3 Three toggles, one Err_ToggleEnd, the node on bus B; the repaired bus B with the master on it ends the process (TC-RM-19)

3. Generic ranges

Generic Declared range Simulated Synthesised (lint/synth_check.py)
MinimalSet_g true, false both both

The consumer heartbeat time, Ttoggle and Ntoggle are inputs. Their bounds are simulated: C = 0, 1 and 65535 (TC-RM-03, TC-RM-04), T = 0, 1 and 255 (TC-RM-03), N = 0 and 255 (TC-RM-08).

4. Negative tests and mutations

Every checker of the plan has a negative test (verification plan, section 5). In addition, 40 deliberate faults of the RTL were each simulated with the tests that must detect them, one of them also in the network bench alone. 37 made a test fail; three change the behaviour only after an upset that the ports cannot inject and are covered by design review:

Fault Detected by
DLC of the master heartbeat not checked TC-RM-02
No Err_HbDlc TC-RM-02
State byte taken from the inactive bus TC-RM-02
Ttoggle = 0 not taken as 1 TC-RM-03
Presence not cleared after C TC-RM-05
Presence set with C = 0 TC-RM-04
Monitoring with C = 0 TC-RM-04
No restart of the timer at a parameter change TC-RM-06
A heartbeat on the inactive bus restarts the timer TC-RM-05, TC-RM-11
A tick in the cycle of a heartbeat counted TC-RM-03, TC-RM-14
No Err_HbMissing TC-RM-03
No Pre-operational request at a missing heartbeat TC-RM-07
First toggle not due at once after a missing heartbeat TC-RM-07
Toggle outside Pre-operational TC-RM-07, TC-RM-13
Ctoggle not counted TC-RM-08
No restart of the timer at a toggle TC-RM-13
No end of the toggling TC-RM-08
Err_ToggleEnd at every due toggle TC-RM-08
End of the process on the active bus without the update of Bdefault TC-RM-09
Message on the inactive bus: no switch TC-RM-10
Switch event before the link reports the new bus TC-RM-07
No Nmt_Switched TC-RM-07
End of the process after a switch by a message without the update of Bdefault TC-RM-10
Message on the requested bus during a switch ignored TC-RM-10
Message on the bus left during a switch taken TC-RM-10
A message of the inactive bus taken before one of the active bus in the same cycle TC-RM-10
Bdefault not read in Idle_s TC-RM-01
Start-up process with a toggle due TC-RM-01, TC-RM-08
Minimal set: start-up bus selection TC-RM-01
Write of Ctoggle ignored TC-RM-12
No repeated Pre-operational request for a due toggle (RM-SL-03) TC-RM-20; TC-RM-25 alone
Idle_s waits in Operational or Stopped (RM-SL-01) TC-RM-21
PresMs compared with = TC-RM-22
Toggle with C = 0 TC-RM-24
Ctoggle not cleared at a missing heartbeat TC-RM-23
Exhausted not cleared at a missing heartbeat TC-RM-23
Ctoggle not cleared at the start-up process TC-RM-01
TmrMs compared with = Not detected; covered by design review
EndAfter not cleared at the start-up process Not detected; covered by design review
EndAfter not cleared at a missing heartbeat Not detected; covered by design review

TmrMs exceeds C - 1 only after an upset, since a change of C restarts the timer, and EndAfter is '1' at the start of a process only after an upset: every path that sets it ends at the end of the switch, which clears it (verification plan, section 7).

Four faults were first not detected, each by a gap of the bench, not of the RTL: "monitoring with C = 0" (TC-RM-04 ran with T = 2, where a timer that ran with C = 0 expires only after 131072 ticks; it now runs with T = 1), "no restart of the timer at a toggle" (the restart matters only for a toggle that waited for Pre-operational; TC-RM-13 now measures the next toggle after such a toggle), "minimal set: start-up bus selection" (no test let the node leave the Initialisation to Pre-operational in the minimal set; TC-RM-01 now does) and "Exhausted not cleared at a missing heartbeat" (a toggle also clears it; TC-RM-23 now runs processes with Ntoggle = 0). After these changes all four are detected.

5. Summary

All 25 test cases pass in all 30 runs; every requirement of the specification is covered by the verification plan. VSG reports no errors and no warnings, and the GHDL synthesis of both configurations has no inferred latch.