ocan_mib: Architecture and Design Description¶
1. Block diagram¶
olo_axi_lite_slave turns the AXI4-Lite accesses into a register bus (Rb_*): one access at a time, a write as a
one-cycle Rb_Wr with the address and the data, a read as a one-cycle Rb_Rd answered with Rb_RdValid in the next
clock cycle, so that the read time-out of the slave never expires. The register file is one two-process record in
Clk; every output towards the core is a register or a function of registers only, so no path leads from an input of
the core to an output. The byte strobes are not used (MB-IF-01). The register map is in
register_map.md; the RTL takes every address and field position from ocan_regs_pkg.
| Access of the slave | Clock cycle of the effect |
|---|---|
| Write | The cycle in which BValid rises: the register takes the value at the end of that cycle |
| Read | The cycle after the read address handshake: the inputs of that cycle form the word, RValid follows two cycles later |
2. Control and bit timing (MB-1)¶
CONTROL.ENABLE and APP_ENABLE are registers; RECOVER, REENABLE_A and REENABLE_B set one-cycle pulses that drive
Ctrl_Recover and Ctrl_Reenable in the clock cycle after the write. BIT_TIMING drives Cfg_*. A write to
BIT_TIMING is taken only while ENABLE is '0' and its fields are in the ranges of olo_intf_can (timingOk: Tseg1 2
to 31, Tseg2 2 to 15, Sjw 1 to min(4, Tseg2)); otherwise the event CFG_REFUSED sets its flag (MB-CT-04). The
prescaler has no forbidden value: olo_intf_can counts 0 as 1. The reset values come from AutoEnable_g,
Prescaler_g, Tseg1_g, Tseg2_g and Sjw_g.
3. Flags, interrupt and counters (MB-2)¶
| Register | Bits | Events |
|---|---|---|
| EVENTS | 9:0 | Sync_Valid, Evt_ResetApp, Evt_ResetComm, Evt_BdefaultUpdate, Evt_TimeSet, Evt_TimeSync, Evt_SdoAbortTx, Evt_SdoAbortRx, Evt_LinkArbLost, a request taken into the mailbox |
| PDO_EVENTS | 23:0 | Rpdo_Valid, Evt_TpdoSent, Evt_TpdoAborted, Err_RpdoLength, Err_TpdoBusy, Err_TpdoTimeout, four bits each |
| ERRORS | 16:0 | The 16 Err_* outputs of the NMT, the redundancy, the object dictionary, the dispatch, the SDO server and the time, and CFG_REFUSED |
| LINK_ERRORS | 13:8, 5:0 | Err_LinkBit, Err_LinkStuff, Err_LinkCrc, Err_LinkForm, Err_LinkAck, Err_LinkDomTimeout of controller B and A |
Each flag register is updated in one statement: next = (flags and not the written ones) or the events of the cycle,
so an event in the clock cycle of the clearing write keeps its flag (MB-FL-01). The interrupt register takes the OR of
all flags and their enables of the next state, so Irq rises in the clock cycle after the event and falls in the
clock cycle after the clearing write. IRQ_STATUS reads the same OR per flag register.
The error counters are twelve 8-bit registers (six per controller). A write to LINK_A_COUNTS0 or LINK_B_COUNTS0 clears the bit, stuff, CRC and form counters of its controller, a write to LINK_A_COUNTS1 or LINK_B_COUNTS1 the acknowledgement and dominant timeout counters; the next value is then the event of the cycle (0 or 1), otherwise the counter adds the event below 255. A read has no effect on the counters (MB-CN-01).
4. PDOs, mailbox and time (MB-3)¶
Receive PDOs. RPDOn_HI reads bits 63 to 32 of the PDO at Rpdo_Data in the read cycle and takes bits 31 to 0
into the register RpdoLo(n), which RPDOn_LO reads; both words therefore come from one clock cycle (MB-PD-01).
Transmit PDOs. TpdoNext(n) holds the words that software writes; TpdoData(n) drives Tpdo_Data. UPDATE copies
TpdoNext(n) into TpdoData(n); REQUEST copies it and sets the one-cycle Tpdo_Req(n - 1) in the same clock edge,
so the core never samples half of an old and half of a new PDO (MB-PD-02). The registers of the absent PDOs are not
generated (loops to NumRpdo_g - 1 and NumTpdo_g - 1) and read zero.
Mailbox. With APP_ENABLE = '1' the port answers App_ReqReady = not PENDING. A request is taken in the clock
cycle in which App_ReqValid is '1' while PENDING is '0'; its fields are stored and PENDING and the event
APP_REQUEST are set. A write of SEND while PENDING is '1' sets the one-cycle App_RspValid with the response registers
and clears PENDING. Err_AppTimeout and APP_ENABLE = '0' clear PENDING: ocan_od has then ended the access, and a
later SEND finds no pending request. With APP_ENABLE = '0' the outputs are the default values of the port
(App_ReqReady = '1', App_RspValid = '1', App_RspAbort = 0602 0000h, data and length 0), so the core answers every
request in the clock cycle after it (OD-AP-04); clearing APP_ENABLE while a request is pending ends it the same way.
| Event in a clock cycle | PENDING next |
|---|---|
| Request taken | '1' |
| SEND while PENDING | '0' |
Err_AppTimeout or APP_ENABLE = '0' |
'0' (also over a request taken in the same cycle) |
| Otherwise | unchanged |
Time. A read of TIME_COARSE returns Time_Coarse and takes Time_Fine into FineSnap, which TIME_FINE reads
(MB-TM-01). REQUEST of TIME_CONTROL sets the one-cycle Time_Req.
5. Error injection (MB-4)¶
With ErrInjRegs_g = true, ERRINJ_SELECT (target, windows w0 and w1), ERRINJ_MASK0, ERRINJ_MASK1 and the level
LINK_TX_DOMINANT are registers; INJECT sets the one-cycle InjPulse and LINK_STOP_FLIP_A and B the one-cycle
StopFlip. During InjPulse the outputs are, for bit i of the selected target:
ErrInj_<target>BitFlip(i) = (Mask0(i mod 32) and w0 = i / 32) or (Mask1(i mod 32) and w1 = i / 32)
ErrInj_<target>Valid = '1'
The decode is a function of registers only, so the 558 bits of ErrInj_OdBitFlip need no register of their own.
Bits beyond the width of a target (window 17 above bit 557, windows 1 to 31 of the NMT target) have no output and
are ignored. With ErrInjRegs_g = false the registers are not written, read zero and the outputs are constant '0',
which synthesis removes (MB-EI-03).
6. Protection¶
ocan_mib holds no parameter of the standard: the protected parameters stay in ocan_od and ocan_dispatch, the
NODE-ID in ocan_nmt. Its registers are covered by the protection scope of the user guide (TMR of the synthesis
tool). Without that TMR an upset of a register gives at most:
- CONTROL.ENABLE: the controllers stop or start until software writes it again;
- BIT_TIMING: a wrong bit timing until software writes it again (a value outside the ranges of
olo_intf_canonly through the upset); - a flag, an enable, a counter: a wrong interrupt or count until software clears it;
- PENDING: a request without its port state (cleared by
Err_AppTimeoutof the core after 256 ticks) or a lost response (the core times out and answers 0800 0000h); - a pulse register: one pulse more or less (a recovery, a request, an injection only with
ErrInjRegs_g).
No upset of a single register stops the register access: olo_axi_lite_slave recovers its FSM in when others, and
every read is answered in the next clock cycle.
7. Ports of ocan_mib¶
| Signal | Direction | Width | Description |
|---|---|---|---|
Clk, Rst |
In | 1 | Clock and synchronous high-active reset |
S_AxiLite_* |
AXI4-Lite slave: ArAddr, AwAddr 9 bits, WData, RData 32 bits, WStrb 4 bits (not used), BResp, RResp 2 bits, handshakes |
||
Irq |
Out | 1 | Interrupt, '1' while an enabled flag is set |
Ctrl_*, Cfg_* |
Out | as ocan_core |
Control and bit timing of ocan_core |
Tpdo_Req, Tpdo_Data |
Out | 4, 256 | Transmit PDOs of ocan_core |
App_ReqReady, App_RspValid, App_RspData, App_RspLen, App_RspAbort |
Out | 1, 1, 64, 4, 32 | Application port of ocan_core |
Time_Req |
Out | 1 | Request of the Local Time PDO |
ErrInj_* |
Out | as ocan_core |
Error injection inputs of ocan_core |
Node_*, Sync_Valid, Rpdo_*, Stat_*, Evt_*, Err_*, App_Req* (in), Time_Coarse, Time_Fine |
In | as ocan_core |
Outputs of ocan_core |
The ports towards the core have the names, widths and layouts of the ports of ocan_core, so that ocan_axi
connects them by name.
8. Configuration parameters¶
The generics of the specification (section 4) and those of ocan_core that GENERICS, DOMINANT_LIMIT and
CLK_FREQUENCY report, with the names, defaults and ranges of ocan_core. Elaboration stops with a message for a
BusAccess_g other than "Selective" and "Parallel" and for Sjw_g above Tseg2_g.
9. Timing and behaviour¶
| Operation | Duration |
|---|---|
| Write: write data handshake to the write | The next clock cycle, in which BValid rises; the register takes the value at its end |
Read: read address handshake to RValid |
3 clock cycles; the word is formed from the inputs of the clock cycle after the handshake |
Event to its flag; flag to Irq |
1 clock cycle; together (the interrupt register takes the next state) |
| Write of a command bit to its pulse | 1 clock cycle after the cycle of the write, for one clock cycle |
| Request of the application port to APP_REQ.PENDING | 1 clock cycle |
SEND to App_RspValid |
1 clock cycle after the cycle of the write |