Description

This component implements a pipeline stage for AXI4 interfaces. The component registers all signals of the interface.

Note that the component can be used for AXI4-Lite by simply leaving all unused signals unconnected.

Generics

Name Type Default Description
Stages_g positive 1 Number of register stages to insert
AddrWidth_g positive 32 With of the AwAddr and ArAddr signals in bits.
DataWidth_g positive 32 Width of the WData and RData signals in bits
IdWidth_g natural 0 Width of the signals AwId, ArId, BId and RId signals in bits.
UserWidth_g natural 0 Width of the siginals AwUser, ArUser, WUser, BUser and RUser in bits.

Interfaces

Control

Name In/Out Length Default Description
Clk in 1 - Clock
Rst in 1 - Reset input (high-active, synchronous to Clk)

AXI Interfaces

Name In/Out Length Default Description
S_... * * * AXI4 slave interface. For the exact meaning of the signals, refer to the AXI protocol specification.
M_... * * * AXI4 master interface. For the exact meaning of the signals, refer to the AXI protocol specification.

Transaction requests are forwarded from the slave interface to the master interfaces. Responses are forwarded from the master interface to the slave interface.

Architecture

The entity is based on the olo_base_pl_stage entity. One such entity is used for every one of the 5 channels AXI4 has.