Skip to content

olo_ft_ecc_monitor

Back to Entity List

Status Information

VHDL Source: olo_ft_ecc_monitor

Description

This component implements an EDAC monitor: it aggregates the SEC/DED indications of up to 255 fault-tolerant instances (RAMs, FIFOs, delays, AXI masters, scrubbers) into per-channel saturating counters with sticky DED flags, countable event pulses and a RAM-style read port with per-channel read-and-clear. It provides the error statistics that housekeeping software needs to track SEU rates and detect degradation trends.

For an AXI4-Lite attached variant, see olo_ft_ecc_monitor_axi.

Generics

Name Type Default Description
Channels_g positive - Number of monitored channels (range 1 to 255). One channel is one SEC/DED source pair (one ft instance, or one port of a dual-port one).
CounterWidth_g positive 16 Width of each saturating counter (range 1 to 16). The 16-bit maximum lets one channel's SEC and DED counters share a single 32-bit register word.

Interfaces

Control

Name In/Out Length Default Description
Clk in 1 - Clock
Rst in 1 - Reset (high-active, synchronous to Clk). Clears all counters and sticky flags.
Clr in 1 '0' Synchronous global clear of all counters and sticky flags. An event arriving in the same cycle is counted after the clear (no lost events).

Event Inputs

Name In/Out Length Default Description
In_EccSec in Channels_g - SEC indication per channel.
In_EccDed in Channels_g - DED indication per channel.
In_Valid in Channels_g all '1' Qualifier per channel; an event is counted in cycles where the flag AND the qualifier are '1'. See Connecting Sources.

Status

Name In/Out Length Default Description
DedSticky out Channels_g N/A Set on the first counted DED per channel, cleared by Rst, Clr or a read-and-clear. This is the safety-critical level signal (data corruption occurred on this channel).
Evt_Sec out 1 N/A High for one cycle per clock cycle in which any channel counted a SEC. Directly countable.
Evt_Ded out 1 N/A Same for DED events.

Read Port

The read port behaves like an olo_base_ram_* read with a read latency of one clock cycle.

Name In/Out Length Default Description
Rd_Channel in ceil(log2(Channels_g)) 0 Channel to read (minimum width 1). Indexes beyond Channels_g-1 return zeros.
Rd_Ena in 1 '0' Read strobe.
Rd_Clr in 1 '0' Together with Rd_Ena: atomically clear the addressed channel (counters and sticky flag) after sampling the read data. An event arriving in the same cycle survives the clear.
Rd_SecCnt out CounterWidth_g N/A SEC counter of the addressed channel.
Rd_DedCnt out CounterWidth_g N/A DED counter of the addressed channel.
Rd_Valid out 1 N/A Read data valid, Rd_Ena delayed by one clock cycle.

Detailed Description

Architecture

The monitor is a single two-process entity without internal storage primitives. The counter file is deliberately implemented in flip-flops, for two reasons:

  1. Correctness: multiple channels can count in the same clock cycle, which a RAM-based counter file (one write port) cannot express.
  2. Fault tolerance: all state stays in flip-flops coverable by vendor TMR, following Open Logic Fault-Tolerance Principles. There is no RAM-resident state and no codeword inside the monitor; consequently this is the one ft entity without ErrInj_BitFlip/ErrInj_Valid ports (there is nothing to flip).

The flip-flop cost is Channels_g x 2 x CounterWidth_g plus the sticky vector; for 16 channels at the default width this is roughly 500 FF before TMR.

Counting Semantics

  • Counters saturate at all-ones and never wrap; a saturated value reads as "at least this many".
  • Clear precedence is fixed: read sampling first, then clear (Clr or Rd_Clr), then counting. An event in the same cycle as a clear is therefore counted after the clear, and a read-and-clear returns the pre-clear value. Only Rst discards events.
  • Evt_Sec/Evt_Ded indicate "at least one channel counted this cycle" with a one-cycle delay, countable per cycle like the status pulses of the other ft entities.

Connecting Sources

The ft entities deliver their status flags in two flavors; the per-channel In_Valid qualifier serves both:

  • Countable pulses (scrub status, AXI master write flags): connect the flag directly and leave In_Valid at its default '1'.
  • Data-aligned flags (FIFO/RAM/delay read flags): qualify with the handshake, e.g. In_Valid(i) <= Out_Valid and Out_Ready for a FIFO or In_Valid(i) <= RdValid for a RAM.

When only some channels need qualification, drive the remaining bits with '1'; the all-'1' default applies only to a fully unconnected port.

The monitor is single-clock. For sources in other clock domains, qualify the flag in its source domain first and cross it as a pulse via olo_ft_cc_pulse.