Skip to content

olo_intf_can

Back to Entity List

Status Information

VHDL Source: olo_intf_can, bit timing helper olo_intf_pkg_can

Description

Overview

This entity implements a CAN 2.0B protocol controller: standard (11-bit) and extended (29-bit) data and remote frames, arbitration, error detection and signalling, fault confinement and bit timing with synchronisation. It connects to a CAN transceiver through Can_Tx and Can_Rx ('1' is the recessive level).

User logic sends and receives whole frames: one beat on Tx_* is one frame to send, one pulse on Rx_Valid is one received frame. The controller retransmits a frame automatically after an error or a lost arbitration until it is sent, aborted or the node goes bus off.

The Can_Rx input is synchronized internally (SyncStages_g, SyncTmr_g).

The protocol follows the Bosch CAN Specification 2.0 (1991), part B. The references in this document name its sections.

Conformance

Part B section Content Implemented
3.1, 3.2.1, 3.2.2 Standard and extended data and remote frames Transmit and receive
3.2.3 Error frames (active and passive error flag, error delimiter) Yes
3.2.4 Overload frames Reaction to overload conditions 2 and 3; condition 1 (a receiver that needs a delay) is never generated
3.2.5 Interframe space, suspend transmission, start of frame in the third intermission bit Yes
3.3 Conformance with regard to frame formats Full extended format support
4 Message filtering Not in the controller: every valid frame is output, see Filtering
5 Message validation Yes
6 Bit stuffing Yes
7 Error detection (bit, stuff, CRC, form, acknowledgment error) and signalling Yes
8 Fault confinement, rules 1 to 12 with both exceptions of rule 3 Yes
9, 10 Bit timing, hard synchronization, resynchronization Yes, programmable at runtime
2 Sleep mode and wake-up No

CAN FD, time-triggered CAN and higher layers are not part of this entity.

Generics

Name Type Default Description
SyncStages_g positive 2 Number of synchronization stages for Can_Rx.
Range: 2 ... 4
SyncTmr_g boolean false Implement the synchronizer as three chains with a majority voter, see clock-crossing principles
AutoRecover_g boolean true true: a bus-off node recovers after 128 occurrences of 11 consecutive recessive bits (section 8 rule 12)
false: the recovery (with the same 128 x 11 recessive bits) starts only after a pulse on Ctrl_Recover

Interfaces

Control

Name In/Out Length Default Description
Clk in 1 - Clock
Rst in 1 - Reset input (high-active, synchronous to Clk)
Ctrl_Recover in 1 '0' Pulse: start the bus-off recovery (only used for AutoRecover_g = false)

Configuration

The configuration must be static while Cfg_Enable = '1'. See Bit Timing for the values.

Name In/Out Length Default Description
Cfg_Enable in 1 '1' '0': the controller does not take part in the bus (Can_Tx recessive). After '1' it integrates (11 recessive bits) before it sends or receives. The error counters and the bus-off state are kept.
Cfg_Prescaler in 10 - Clock cycles per time quantum
Range: 1 ... 1023 (0 is treated as 1)
Cfg_Tseg1 in 5 - PROP_SEG + PHASE_SEG1 in time quanta
Range: 2 ... 31
Cfg_Tseg2 in 4 - PHASE_SEG2 in time quanta
Range: 2 ... 15
Cfg_Sjw in 3 - Resynchronization jump width in time quanta
Range: 1 ... min(4, PHASE_SEG1, Cfg_Tseg2)
Cfg_ListenOnly in 1 '0' '1': the controller receives but never drives the bus: no acknowledge, no error or overload flags, no transmission; the error counters do not change
Cfg_Loopback in 1 '0' '1': the transmitted bits are looped back internally, Can_Tx stays recessive. The controller acknowledges its own frames and outputs them on Rx_* (self test).

Transmit Frame

Name In/Out Length Default Description
Tx_Valid in 1 '0' AXI4-Stream handshaking signal for the frame
Tx_Ready out 1 N/A AXI4-Stream handshaking signal for the frame: '1' while no frame is pending
Tx_Id in 29 0 Identifier. Standard frames: bits 28 ... 18 (bits 17 ... 0 are ignored)
Tx_Ide in 1 '0' '1': extended frame (29-bit identifier)
Tx_Rtr in 1 '0' '1': remote frame (no data field)
Tx_Dlc in 4 0 Data length code; 9 ... 15 send 8 bytes
Tx_Data in 64 0 Data bytes, byte 0 (sent first) in bits 63 ... 56
Tx_Abort in 1 '0' Pulse: drop the pending frame. A frame that is on the bus is completed: Tx_Done on success, otherwise it is dropped instead of retransmitted.
Tx_Done out 1 N/A Pulse: the frame was sent (no error up to the end of the end of frame field)
Tx_Aborted out 1 N/A Pulse: the frame was dropped after Tx_Abort
Tx_ArbLost out 1 N/A Pulse: the frame lost the arbitration (it is retransmitted later)

Receive Frame

There is no Ready signal (a CAN receiver cannot delay the bus): the user must accept every frame. Use a FIFO (e.g. olo_base_fifo_sync or olo_ft_fifo_sync) if the frames cannot be processed at once.

Name In/Out Length Default Description
Rx_Valid out 1 N/A Pulse: a valid frame was received (no error up to the last but one bit of the end of frame field)
Rx_Id out 29 N/A Identifier (standard frames: bits 28 ... 18, bits 17 ... 0 are 0)
Rx_Ide out 1 N/A '1': extended frame
Rx_Rtr out 1 N/A '1': remote frame
Rx_Dlc out 4 N/A Data length code as received
Rx_Data out 64 N/A Data bytes, byte 0 in bits 63 ... 56; bytes beyond the data length are 0

The Rx_* signals are valid together with Rx_Valid only.

Status and Error Events

Name In/Out Length Default Description
Stat_Tec out 9 N/A Transmit error count
Stat_Rec out 8 N/A Receive error count (saturates at 255)
Stat_State out 2 N/A "00": error active, "01": error passive, "11": bus off
Stat_BusIdle out 1 N/A '1' while the bus is idle
Err_Bit out 1 N/A Pulse: bit error detected
Err_Stuff out 1 N/A Pulse: stuff error detected
Err_Crc out 1 N/A Pulse: CRC error detected (at the start of the error flag after the ACK delimiter)
Err_Form out 1 N/A Pulse: form error detected
Err_Ack out 1 N/A Pulse: acknowledgment error detected

CAN Interface

Name In/Out Length Default Description
Can_Tx out 1 N/A To the transceiver ('1' = recessive)
Can_Rx in 1 '1' From the transceiver ('1' = recessive)

Detailed Description

Bit Timing

A bit consists of time quanta of Cfg_Prescaler clock cycles: one quantum SYNC_SEG, Cfg_Tseg1 quanta PROP_SEG + PHASE_SEG1 and Cfg_Tseg2 quanta PHASE_SEG2 (section 10). The bus is sampled at the end of PHASE_SEG1, a new bit is driven at the start of SYNC_SEG.

bit rate     = clock frequency / (Cfg_Prescaler * (1 + Cfg_Tseg1 + Cfg_Tseg2))
sample point = (1 + Cfg_Tseg1) / (1 + Cfg_Tseg1 + Cfg_Tseg2)

PROP_SEG must cover twice the delay of the bus line, the transceiver and the input synchronizer (SyncStages_g + 1 clock cycles). The controller needs one clock cycle after the sample point to compute the next bit, so the information processing time is below one time quantum; Cfg_Tseg2 = 2 is the smallest value the Bosch rules allow (PHASE_SEG2 not shorter than an information processing time of 2 quanta).

Synchronization (section 10):

  • A hard synchronization restarts the bit at a recessive-to-dominant edge while the bus is idle (start of frame), also during integration, suspend transmission and bus off.
  • Within a frame, recessive-to-dominant edges resynchronize the bit: PHASE_SEG1 is lengthened or PHASE_SEG2 shortened by the phase error, at most Cfg_Sjw quanta. Only one synchronization happens between two sample points, only after a recessive sample, and a node that sends a dominant bit ignores edges with a positive phase error.

The package olo_intf_pkg_can computes a configuration for a clock, a bit rate and a sample point:

library olo;
    use olo.olo_intf_pkg_can.all;
    use olo.olo_base_pkg_math.all;

constant Bt_c : CanBitTiming_t := canBitTiming(ClkFreq => 50.0e6, BitRate => 500.0e3, SamplePoint => 0.75);

i_can : entity olo.olo_intf_can
    port map (
        Clk           => Clk,
        Rst           => Rst,
        Cfg_Prescaler => toUslv(Bt_c.Prescaler, 10),
        Cfg_Tseg1     => toUslv(Bt_c.Tseg1, 5),
        Cfg_Tseg2     => toUslv(Bt_c.Tseg2, 4),
        Cfg_Sjw       => toUslv(Bt_c.Sjw, 3),
        ...
    );

canBitTiming chooses 8 to 25 time quanta per bit with the smallest bit rate error (more quanta at equal error), places the sample point as close to SamplePoint as possible within the Bosch ranges (PROP_SEG and PHASE_SEG1 1 to 8 quanta each, PHASE_SEG2 2 to 8 quanta) and sets SJW to min(4, PHASE_SEG1, PHASE_SEG2). It stops with a failure if no setting reaches the bit rate within MaxRateError (default 0.1 %). Tying the ports to these constants gives a controller with a fixed bit rate.

PHASE_SEG2 is programmable independently of PHASE_SEG1. Bosch 2.0 defines PHASE_SEG2 as the maximum of PHASE_SEG1 and the information processing time; later sample points (for example 87.5 %) need the independent setting.

The oscillator tolerance of a setting follows from the usual conditions (bit time in quanta):

df <= SJW / (20 * bit time)
df <= min(PHASE_SEG1, PHASE_SEG2) / (2 * (13 * bit time - PHASE_SEG2))

The 1.58 % of section 9 need for example 10 quanta with PHASE_SEG2 = 4 and SJW = 4.

Transmission

A frame is taken with Tx_Valid while Tx_Ready = '1' and stays pending until Tx_Done or Tx_Aborted. The controller starts it at the first bit of bus idle, or in the third bit of the intermission when another node starts a frame there (section 3.2.5: the controller then continues with the identifier). After a lost arbitration (Tx_ArbLost) the controller receives the other frame and retries afterwards; after an error it retransmits after the error frame and the interframe space.

An error passive transmitter waits 8 more bits after the intermission (suspend transmission) before it starts a new frame.

Reception

Every valid frame is output, also remote frames and frames with a data length code above 8 (Rx_Dlc as received, 8 data bytes). The controller acknowledges every frame with a correct CRC (not in listen-only mode). Frames sent by the controller itself are not output, except in loopback mode.

Filtering

The controller has no acceptance filter (section 4 makes it optional). Because Rx_* has no back pressure, a filter on the receive frames is equivalent and can be any logic, for example a mask and a code:

Accept <= Rx_Valid when (Rx_Id and Mask_c) = (Code_c and Mask_c) and Rx_Ide = Ide_c else '0';

Error Handling and Fault Confinement

Detected errors are signalled with an error flag (section 7.2): an active error flag (6 dominant bits) when the node is error active, a passive error flag (6 recessive bits) when it is error passive. CRC errors are flagged after the ACK delimiter, all others in the bit after the error. Every error pulses one of the Err_* outputs.

The transmit and receive error counts follow the rules of section 8, including:

  • exception 1 of rule 3: an error passive transmitter without acknowledge does not increase its count unless it sees a dominant bit during its passive error flag (so a single node on a bus becomes error passive, but not bus off);
  • exception 2 of rule 3: a stuff error on a recessive stuff bit of the arbitration field that is monitored dominant;
  • rule 8: a successful reception decrements the receive count; a count above 127 is set to 119.

The node is error passive for a count of 128 or more and bus off for a transmit count of 256 or more. A bus-off node keeps Can_Tx recessive, keeps a pending frame and recovers (both counts 0, error active) after 128 occurrences of 11 consecutive recessive bits. With AutoRecover_g = false, the counting starts only after a pulse on Ctrl_Recover, so the user decides when a node rejoins the bus (for example when redundant buses are managed by a higher layer).

Modes

  • Listen-only (Cfg_ListenOnly = '1'): monitoring without influence on the bus. Errors are detected and pulsed, but the counters do not change and no flag is sent. A pending frame is not started.
  • Loopback (Cfg_Loopback = '1'): the controller receives its own bits and acknowledges its own frames; Can_Tx stays recessive, the bus is ignored.
  • Disabled (Cfg_Enable = '0'): Can_Tx recessive, no participation. After enabling, the controller integrates again (11 recessive bits); the error counters and the bus-off state are kept (disabling does not bypass the bus-off recovery).

Protection

The controller has no memories; its registers are protected by the TMR of the synthesis tool if required. Every state machine returns to integration from any illegal state.